Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

364

matching recommendations
Reset
SIC 348 Ordnance And Accessories, Nec
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0421 # 05 Y:2011 05 2011 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $5,567 $10,314 Not Implemented
WV0421 # 06 Y:2011 06 2011 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $5,339 $3,000 Not Implemented
WV0421 # 07 Y:2011 07 2011 DEVELOP A REPAIR/REPLACE POLICY $4,203 $841 Implemented
WV0421 # 08 Y:2011 08 2011 INSULATE BARE EQUIPMENT $4,166 $1,910 Implemented
WV0421 # 09 Y:2011 09 2011 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $4,091 $1,163 Not Implemented
WV0421 # 10 Y:2011 10 2011 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,731 $21 Implemented
WV0421 # 11 Y:2011 11 2011 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $2,484 $8,964 Not Implemented
WV0421 # 12 Y:2011 12 2011 ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM $2,007 $3,000 Implemented
WV0421 # 13 Y:2011 13 2011 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,849 $386 Implemented
WV0421 # 14 Y:2011 14 2011 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $1,352 $1,551 Not Implemented
WV0421 # 15 Y:2011 15 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $294 $241 Implemented
WV0421 # 16 Y:2011 16 2011 TURN OFF EQUIPMENT WHEN NOT IN USE $266 $191 Implemented
LL0324 # 01 Y:2009 01 2009 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $51,066 $5,850 Implemented
LL0324 # 02 Y:2009 02 2009 BEGIN A PRACTICE OF PREDICTIVE / PREVENTATIVE MAINTENANCE $3,552 $1,140 Not Implemented
LL0324 # 03 Y:2009 03 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,908 $265 Not Implemented
LL0324 # 04 Y:2009 04 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,689 $1,050 Not Implemented
LL0324 # 05 Y:2009 05 2009 CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES $1,089 $1,246 Not Implemented
LL0324 # 06 Y:2009 06 2009 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $258 $120 Not Implemented
LL0324 # 07 Y:2009 07 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $158 $1,435 Not Implemented
LL0324 # 08 Y:2009 08 2009 INSTALL OCCUPANCY SENSORS $142 $270 Not Implemented
UA0036 # 04 Y:2009 04 2009 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $29,387 $40,768 Implemented
UA0036 # 01 Y:2009 01 2009 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $10,392 $0 Implemented
UA0036 # 02 Y:2009 02 2009 INSTALL TIMERS AND/OR THERMOSTATS $3,429 $1,700 Implemented
UA0036 # 03 Y:2009 03 2009 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $15,005 $15,600 Not Implemented
UA0036 # 05 Y:2009 05 2009 RECOVER WASTE HEAT FROM EQUIPMENT $6,452 $10,320 Not Implemented