Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
37
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
TN0263 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,113 | $11,950 | Implemented |
ST0047 # 05 Y:1985 | 05 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $382 | $1,100 | Implemented |
ST0047 # 03 Y:1985 | 03 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,188 | $120 | Implemented |
ST0047 # 01 Y:1985 | 01 | 1985 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,895 | $16,240 | Implemented |
LT0050 # 03 Y:1985 | 03 | 1985 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $929 | $2,700 | Implemented |
LT0050 # 01 Y:1985 | 01 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $8,567 | $900 | Implemented |
ST0047 # 07 Y:1985 | 07 | 1985 | INSTALL STORM WINDOWS AND DOORS | $1,148 | $2,025 | Implemented |
ST0047 # 08 Y:1985 | 08 | 1985 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,210 | $0 | Implemented |
ST0047 # 09 Y:1985 | 09 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $617 | $200 | Implemented |
ST0047 # 13 Y:1985 | 13 | 1985 | ADD AIR SHIELDS TO TRUCKS TO INCREASE FUEL MILEAGE | $3,050 | $6,397 | Implemented |
TN0263 # 03 Y:1985 | 03 | 1985 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $1,318 | $0 | Implemented |
ST0047 # 11 Y:1985 | 11 | 1985 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $119 | $0 | Implemented |
ST0042 # 07 Y:1985 | 07 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $599 | $70 | Implemented |
ST0042 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,086 | $200 | Implemented |
GT0267 # 06 Y:1985 | 06 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $1,860 | $1,000 | Implemented |
ST0042 # 05 Y:1985 | 05 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $799 | $537 | Implemented |
ST0042 # 04 Y:1985 | 04 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,863 | $2,700 | Implemented |
GT0267 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,640 | $450 | Implemented |
GT0267 # 03 Y:1985 | 03 | 1985 | COVER OPEN TANKS | $3,200 | $600 | Implemented |
TN0257 # 05 Y:1985 | 05 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,048 | $450 | Implemented |
GT0263 # 06 Y:1985 | 06 | 1985 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $21,300 | $400 | Implemented |
GT0263 # 05 Y:1985 | 05 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $787 | $3,679 | Implemented |
GT0263 # 01 Y:1985 | 01 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,700 | $82,000 | Implemented |
OK0160 # 02 Y:1985 | 02 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $3,464 | $300 | Implemented |
OK0160 # 01 Y:1985 | 01 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $622 | $100 | Implemented |