Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,115
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UF0183 # 05 Y:1997 | 05 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,573 | $0 | Not Implemented |
UF0183 # 06 Y:1997 | 06 | 1997 | OPTIMIZE PLANT POWER FACTOR | $9,095 | $36,500 | Not Implemented |
UF0183 # 07 Y:1997 | 07 | 1997 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $58,776 | $0 | Not Implemented |
UF0183 # 08 Y:1997 | 08 | 1997 | IMPROVE HANDLING PRACTICES | $12,852 | $6,000 | Not Implemented |
UF0183 # 09 Y:1997 | 09 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $18,562 | $8,530 | Not Implemented |
MS0087 # 01 Y:1997 | 01 | 1997 | OPTIMIZE PLANT POWER FACTOR | $5,870 | $1,500 | Implemented |
MS0087 # 02 Y:1997 | 02 | 1997 | DISCONNECT BALLASTS | $313 | $150 | Implemented |
MS0087 # 03 Y:1997 | 03 | 1997 | USE SYNTHETIC LUBRICANT | $1,944 | $275 | Implemented |
MS0087 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,232 | $7,102 | Implemented |
MS0087 # 05 Y:1997 | 05 | 1997 | REPAIR FURNACES AND OVEN DOORS SO THAT THEY SEAL EFFICIENTLY | $1,607 | $561 | Implemented |
MS0087 # 06 Y:1997 | 06 | 1997 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $6,564 | $11,519 | Not Implemented |
MS0087 # 07 Y:1997 | 07 | 1997 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $2,400 | $0 | Implemented |
MS0087 # 08 Y:1997 | 08 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $46,844 | $20,800 | Not Implemented |
NC0116 # 01 Y:1997 | 01 | 1997 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,301 | $690 | Implemented |
NC0116 # 02 Y:1997 | 02 | 1997 | INSULATE BARE EQUIPMENT | $2,743 | $188 | Implemented |
NC0116 # 03 Y:1997 | 03 | 1997 | USE OPTIMUM THICKNESS INSULATION | $6,052 | $447 | Implemented |
NC0116 # 04 Y:1997 | 04 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $3,450 | $480 | Not Implemented |
NC0116 # 05 Y:1997 | 05 | 1997 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $13,840 | $1,350 | Not Implemented |
NC0116 # 06 Y:1997 | 06 | 1997 | MOVE PRODUCT USING MECHANICAL MEANS | $101 | $250 | Not Implemented |
BD0084 # 01 Y:1997 | 01 | 1997 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $7,581 | $5,500 | Implemented |
BD0084 # 02 Y:1997 | 02 | 1997 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $7,164 | $3,500 | Not Implemented |
BD0084 # 03 Y:1997 | 03 | 1997 | INSULATE BARE EQUIPMENT | $4,774 | $6,850 | Not Implemented |
BD0084 # 04 Y:1997 | 04 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,816 | $4,933 | Not Implemented |
BD0084 # 05 Y:1997 | 05 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,205 | $11,750 | Not Implemented |
BD0084 # 06 Y:1997 | 06 | 1997 | INSTALL OCCUPANCY SENSORS | $1,580 | $675 | Not Implemented |