Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,115
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ST0042 # 04 Y:1985 | 04 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,863 | $2,700 | Implemented |
ST0042 # 05 Y:1985 | 05 | 1985 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $799 | $537 | Implemented |
ST0042 # 06 Y:1985 | 06 | 1985 | INSTALL AUTOMATIC STACK DAMPER | $1,762 | $1,640 | Not Implemented |
ST0042 # 07 Y:1985 | 07 | 1985 | REPLACE BROKEN WINDOWS AND/OR WINDOW SASH | $599 | $70 | Implemented |
ST0042 # 08 Y:1985 | 08 | 1985 | USE SOLAR HEAT TO HEAT WATER | $447 | $0 | Not Implemented |
GT0267 # 01 Y:1985 | 01 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,275 | $3,300 | Not Implemented |
GT0267 # 02 Y:1985 | 02 | 1985 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $1,200 | $16,250 | Not Implemented |
GT0267 # 03 Y:1985 | 03 | 1985 | COVER OPEN TANKS | $3,200 | $600 | Implemented |
GT0267 # 04 Y:1985 | 04 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,640 | $450 | Implemented |
GT0267 # 05 Y:1985 | 05 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $3,968 | $3,547 | Not Implemented |
GT0267 # 06 Y:1985 | 06 | 1985 | AIR CONDITION ONLY SPACE NECESSARY | $1,860 | $1,000 | Implemented |
TN0257 # 01 Y:1985 | 01 | 1985 | USE HEAT PUMP FOR SPACE CONDITIONING | $17,233 | $429,000 | Not Implemented |
TN0257 # 02 Y:1985 | 02 | 1985 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $8,904 | $37,200 | Not Implemented |
TN0257 # 03 Y:1985 | 03 | 1985 | COVER OPEN TANKS | $3,102 | $200 | Not Implemented |
TN0257 # 04 Y:1985 | 04 | 1985 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,915 | $0 | Not Implemented |
TN0257 # 05 Y:1985 | 05 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,048 | $450 | Implemented |
PV0004 # 01 Y:1985 | 01 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $36,014 | $129 | Not Implemented |
PV0004 # 02 Y:1985 | 02 | 1985 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $15,526 | $27 | Not Implemented |
PV0004 # 03 Y:1985 | 03 | 1985 | USE RADIANT HEATER FOR SPOT HEATING | $1,012 | $4,800 | Not Implemented |
PV0004 # 04 Y:1985 | 04 | 1985 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $616 | $1,181 | Not Implemented |
PV0004 # 05 Y:1985 | 05 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,166 | $79 | Not Implemented |
PV0004 # 06 Y:1985 | 06 | 1985 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $15,428 | $0 | Not Implemented |
GT0263 # 01 Y:1985 | 01 | 1985 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $58,700 | $82,000 | Implemented |
GT0263 # 02 Y:1985 | 02 | 1985 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,934 | $75 | Not Implemented |
GT0263 # 03 Y:1985 | 03 | 1985 | RE-USE OR RECYCLE HOT OR COLD PROCESS EXHAUST AIR | $1,500 | $3,000 | Not Implemented |