Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
102
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0321 # 01 Y:1995 | 01 | 1995 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,070 | $410 | Implemented |
CO0321 # 02 Y:1995 | 02 | 1995 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $1,600 | $9,960 | Not Implemented |
CO0321 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $670 | $830 | Implemented |
CO0321 # 04 Y:1995 | 04 | 1995 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $410 | $250 | Implemented |
CO0321 # 05 Y:1995 | 05 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $230 | $100 | Not Implemented |
CO0292 # 02 Y:1994 | 02 | 1994 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,930 | $2,400 | Implemented |
CO0292 # 08 Y:1994 | 08 | 1994 | INSULATE BARE EQUIPMENT | $360 | $610 | Not Implemented |
CO0292 # 07 Y:1994 | 07 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $460 | $300 | Implemented |
CO0292 # 06 Y:1994 | 06 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $910 | $2,080 | Implemented |
CO0292 # 05 Y:1994 | 05 | 1994 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $1,150 | $4,660 | Not Implemented |
CO0292 # 04 Y:1994 | 04 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,630 | $3,840 | Implemented |
CO0292 # 03 Y:1994 | 03 | 1994 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,860 | $250 | Implemented |
CO0292 # 01 Y:1994 | 01 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,990 | $4,690 | Implemented |
CO0269 # 04 Y:1993 | 04 | 1993 | RECOVER WASTE HEAT FROM EQUIPMENT | $590 | $1,100 | Not Implemented |
CO0269 # 07 Y:1993 | 07 | 1993 | REDUCE AIR CONDITIONING LOAD BY EVAPORATING WATER FROM ROOF | $1,980 | $9,300 | Not Implemented |
CO0269 # 06 Y:1993 | 06 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,950 | $3,110 | Implemented |
CO0269 # 08 Y:1993 | 08 | 1993 | USE SYNTHETIC LUBRICANT | $320 | $440 | Not Implemented |
CO0269 # 01 Y:1993 | 01 | 1993 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $920 | $200 | Implemented |
CO0269 # 03 Y:1993 | 03 | 1993 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $460 | $600 | Not Implemented |
CO0269 # 05 Y:1993 | 05 | 1993 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $9,350 | $17,000 | Not Implemented |
CO0269 # 02 Y:1993 | 02 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $650 | $180 | Implemented |
CO0255 # 05 Y:1992 | 05 | 1992 | UPGRADE CONTROLS ON COMPRESSORS | $470 | $300 | Not Implemented |
CO0255 # 06 Y:1992 | 06 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,100 | $2,840 | Not Implemented |
CO0255 # 07 Y:1992 | 07 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $430 | $220 | Not Implemented |
CO0255 # 08 Y:1992 | 08 | 1992 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,110 | $3,200 | Not Implemented |