Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
177
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WI0406 # 03 Y:2001 | 03 | 2001 | INSTALL TIMERS AND/OR THERMOSTATS | $3,632 | $600 | Not Implemented |
WI0406 # 05 Y:2001 | 05 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,901 | $0 | Not Implemented |
WI0406 # 01 Y:2001 | 01 | 2001 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $8,841 | $0 | Implemented |
WI0406 # 02 Y:2001 | 02 | 2001 | OPTIMIZE PLANT POWER FACTOR | $7,981 | $14,550 | Not Implemented |
WI0406 # 04 Y:2001 | 04 | 2001 | INSTALL OCCUPANCY SENSORS | $3,556 | $3,880 | Not Implemented |
WI0406 # 06 Y:2001 | 06 | 2001 | REPLACE CLOTH RAGS WITH PAPER TOWELS | $1,063 | $0 | Not Implemented |
WV0227 # 08 Y:2001 | 08 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $12,200 | $1,000 | Implemented |
WV0227 # 01 Y:2001 | 01 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,919 | $750 | Implemented |
WV0227 # 11 Y:2001 | 11 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,814 | $100 | Implemented |
WV0227 # 12 Y:2001 | 12 | 2001 | ADJUST PH FOR NEUTRALIZATION | $8,625 | $13,725 | Not Implemented |
WV0227 # 14 Y:2001 | 14 | 2001 | $110,000 | $85,000 | Not Implemented | |
WV0227 # 13 Y:2001 | 13 | 2001 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $1,200 | $75 | Implemented |
WV0227 # 03 Y:2001 | 03 | 2001 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $913 | $100 | Implemented |
WV0227 # 02 Y:2001 | 02 | 2001 | USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING | $1,589 | $1,980 | Not Implemented |
WV0227 # 06 Y:2001 | 06 | 2001 | INSULATE BARE EQUIPMENT | $275 | $112 | Implemented |
WV0227 # 05 Y:2001 | 05 | 2001 | USE EXCESS COLD PROCESS FLUID FOR INDUSTRIAL COOLING NEEDS | $603 | $390 | Implemented |
WV0227 # 04 Y:2001 | 04 | 2001 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $704 | $50 | Not Implemented |
WV0227 # 10 Y:2001 | 10 | 2001 | RECOVER WASTE HEAT FROM EQUIPMENT | $16,267 | $3,000 | Not Implemented |
WV0227 # 09 Y:2001 | 09 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,150 | $2,910 | Implemented |
WV0227 # 07 Y:2001 | 07 | 2001 | ESTABLISH A PREDICTIVE MAINTENANCE PROGRAM | $31,855 | $2,000 | Implemented |
WV0219 # 07 Y:2001 | 07 | 2001 | USE PHOTOCELL CONTROLS | $548 | $300 | Not Implemented |
WV0219 # 08 Y:2001 | 08 | 2001 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,318 | $40 | Implemented |
WV0219 # 06 Y:2001 | 06 | 2001 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,137 | $21,787 | Implemented |
WV0219 # 05 Y:2001 | 05 | 2001 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $209 | $100 | Not Implemented |
WV0219 # 09 Y:2001 | 09 | 2001 | INSULATE BARE EQUIPMENT | $1,097 | $64 | Implemented |