Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
5,115
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MS0264 # 03 Y:2004 | 03 | 2004 | AIR CONDITION ONLY SPACE NECESSARY | $2,457 | $480 | Not Implemented |
MS0264 # 04 Y:2004 | 04 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,356 | $1,624 | Not Implemented |
MS0264 # 05 Y:2004 | 05 | 2004 | INSTALL TIMERS AND/OR THERMOSTATS | $989 | $944 | Not Implemented |
MS0264 # 06 Y:2004 | 06 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $183 | $249 | Not Implemented |
IC0090 # 01 Y:2004 | 01 | 2004 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $17,317 | $0 | Implemented |
IC0090 # 02 Y:2004 | 02 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,918 | $300 | Implemented |
IC0090 # 03 Y:2004 | 03 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $6,932 | $425 | Not Implemented |
IC0090 # 04 Y:2004 | 04 | 2004 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,643 | $9,400 | Implemented |
IC0090 # 05 Y:2004 | 05 | 2004 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $559 | $77 | Implemented |
IC0090 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,205 | $30,427 | Not Implemented |
CO0555 # 01 Y:2004 | 01 | 2004 | REVISE SMOKE CLEANUP FROM OPERATIONS | $4,790 | $13,100 | Implemented |
CO0555 # 02 Y:2004 | 02 | 2004 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $900 | $580 | Implemented |
CO0555 # 03 Y:2004 | 03 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $186 | $260 | Implemented |
CO0555 # 04 Y:2004 | 04 | 2004 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $220 | $420 | Not Implemented |
CO0555 # 05 Y:2004 | 05 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $13,890 | $37,430 | Not Implemented |
CO0555 # 06 Y:2004 | 06 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,540 | $4,990 | Not Implemented |
CO0555 # 07 Y:2004 | 07 | 2004 | INSTALL OCCUPANCY SENSORS | $120 | $390 | Not Implemented |
BD0273 # 01 Y:2004 | 01 | 2004 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,813 | $3,470 | Implemented |
BD0273 # 02 Y:2004 | 02 | 2004 | INSTALL WIND POWERED ELECTRIC GENERATOR | $10,682 | $50,000 | Implemented |
BD0273 # 03 Y:2004 | 03 | 2004 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $6,786 | $3,000 | Implemented |
BD0273 # 04 Y:2004 | 04 | 2004 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,606 | $4,270 | Implemented |
BD0273 # 05 Y:2004 | 05 | 2004 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,942 | $255 | Implemented |
BD0273 # 06 Y:2004 | 06 | 2004 | INSTALL OCCUPANCY SENSORS | $2,608 | $1,725 | Implemented |
BD0273 # 07 Y:2004 | 07 | 2004 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,185 | $2,900 | Implemented |
BD0273 # 08 Y:2004 | 08 | 2004 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,098 | $0 | Implemented |