Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
47
matching recommendationsSIC | 349 | Misc. Fabricated Metal Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0064 # 06 Y:1982 | 06 | 1982 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $586 | $0 | Implemented |
OK0064 # 05 Y:1982 | 05 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $485 | $0 | Implemented |
OK0064 # 04 Y:1982 | 04 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,749 | $560 | Implemented |
OK0064 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,330 | $1,405 | Implemented |
OK0064 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $1,830 | $400 | Implemented |
OK0064 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $707 | $56 | Implemented |
OK0059 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $204 | $600 | Not Implemented |
UD0051 # 05 Y:1982 | 05 | 1982 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $3,312 | $1,500 | Not Implemented |
UD0051 # 04 Y:1982 | 04 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $4,504 | $900 | Implemented |
UD0051 # 03 Y:1982 | 03 | 1982 | CLOSE HOLES AND OPENINGS IN BUILDING SUCH AS BROKEN WINDOWS | $4,219 | $6,160 | Implemented |
UD0051 # 02 Y:1982 | 02 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,295 | $753 | Implemented |
UD0051 # 01 Y:1982 | 01 | 1982 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $460 | $0 | Implemented |
OK0059 # 06 Y:1982 | 06 | 1982 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,097 | $984 | Implemented |
OK0059 # 05 Y:1982 | 05 | 1982 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $422 | $500 | Not Implemented |
OK0059 # 04 Y:1982 | 04 | 1982 | LOWER CEILING TO REDUCE CONDITIONED SPACE | $230 | $1,137 | Implemented |
OK0059 # 03 Y:1982 | 03 | 1982 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $122 | $0 | Not Implemented |
OK0059 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $473 | $283 | Not Implemented |
OK0046 # 05 Y:1982 | 05 | 1982 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $1,710 | $0 | Not Implemented |
OK0046 # 04 Y:1982 | 04 | 1982 | INSULATE BARE EQUIPMENT | $82 | $288 | Not Implemented |
OK0046 # 03 Y:1982 | 03 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $13,800 | $148 | Implemented |
OK0046 # 02 Y:1982 | 02 | 1982 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $88 | $28 | Not Implemented |
OK0046 # 01 Y:1982 | 01 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $905 | $244 | Not Implemented |
OK0051 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,367 | $200 | Implemented |
OK0051 # 02 Y:1982 | 02 | 1982 | RECOVER WASTE HEAT FROM EQUIPMENT | $3,675 | $3,000 | Implemented |
OK0051 # 03 Y:1982 | 03 | 1982 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $13,620 | $8,300 | Not Implemented |