Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
462
matching recommendationsSIC | 3491 | Industrial Valves |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
IA0126 # 05 Y:1995 | 05 | 1995 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $967 | $2,222 | Implemented |
IA0126 # 06 Y:1995 | 06 | 1995 | INSTALL OCCUPANCY SENSORS | $1,238 | $2,071 | Implemented |
IA0126 # 07 Y:1995 | 07 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,106 | $2,454 | Not Implemented |
IA0126 # 08 Y:1995 | 08 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,304 | $341 | Implemented |
OK0472 # 01 Y:1995 | 01 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $10,844 | $19,582 | Implemented |
OK0472 # 02 Y:1995 | 02 | 1995 | INSTALL SET-BACK TIMERS | $4,881 | $775 | Implemented |
OK0472 # 03 Y:1995 | 03 | 1995 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,501 | $5,713 | Implemented |
OK0472 # 04 Y:1995 | 04 | 1995 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,180 | $0 | Not Implemented |
OK0472 # 05 Y:1995 | 05 | 1995 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,174 | $538 | Not Implemented |
OK0472 # 06 Y:1995 | 06 | 1995 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $1,475 | $4,275 | Implemented |
OK0472 # 07 Y:1995 | 07 | 1995 | OPTIMIZE PLANT POWER FACTOR | $480 | $4,180 | Not Implemented |
MS0007 # 01 Y:1994 | 01 | 1994 | SHIFT FROM DAYTIME TO NIGHTTIME OPERATION | $17,327 | $0 | Not Implemented |
MS0007 # 02 Y:1994 | 02 | 1994 | USE RADIANT HEATER FOR SPOT HEATING | $13,927 | $18,600 | Not Implemented |
MS0007 # 03 Y:1994 | 03 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $1,345 | $5,560 | Implemented |
MS0007 # 04 Y:1994 | 04 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,319 | $1,000 | Not Implemented |
MS0007 # 05 Y:1994 | 05 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $319 | $109 | Implemented |
AM0201 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $37,480 | $3,520 | Implemented |
AM0201 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $18,700 | $26,650 | Not Implemented |
AM0201 # 03 Y:1994 | 03 | 1994 | PAY UTILITY BILLS ON TIME | $1,915 | $0 | Implemented |
AR0015 # 01 Y:1993 | 01 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,666 | $740 | Not Implemented |
AR0015 # 02 Y:1993 | 02 | 1993 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $14,046 | $6,750 | Not Implemented |
AR0015 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,562 | $1,000 | Implemented |
AR0015 # 04 Y:1993 | 04 | 1993 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $5,187 | $14,712 | Not Implemented |
AR0015 # 05 Y:1993 | 05 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $18,409 | $5,000 | Not Implemented |
AR0015 # 06 Y:1993 | 06 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $25,253 | $12,000 | Not Implemented |