Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
661
matching recommendationsSIC | 3496 | Misc. Fabricated Wire Products |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DS0024 # 07 Y:1995 | 07 | 1995 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $176 | $240 | Not Implemented |
DS0024 # 08 Y:1995 | 08 | 1995 | INSTALL TIMERS AND/OR THERMOSTATS | $899 | $1,050 | Not Implemented |
MA0321 # 01 Y:1995 | 01 | 1995 | USE FOSSIL FUEL POWERED GENERATOR DURING PEAK DEMAND PERIODS | $22,525 | $60,000 | Implemented |
MA0321 # 02 Y:1995 | 02 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,118 | $3,888 | Not Implemented |
MA0321 # 03 Y:1995 | 03 | 1995 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,493 | $23,880 | Implemented |
ME0133 # 01 Y:1994 | 01 | 1994 | OPTIMIZE PLANT POWER FACTOR | $2,688 | $4,500 | Not Implemented |
ME0133 # 02 Y:1994 | 02 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $18,453 | $6,650 | Not Implemented |
ME0133 # 03 Y:1994 | 03 | 1994 | USE SMALL NUMBER OF HIGH OUTPUT UNITS INSTEAD OF MANY SMALL INEFFICIENT UNITS | $5,276 | $7,200 | Not Implemented |
NC0022 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,088 | $90 | Implemented |
NC0022 # 02 Y:1994 | 02 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $309 | $10 | Implemented |
NC0022 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,432 | $1,592 | Implemented |
NC0022 # 04 Y:1994 | 04 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $5,119 | $9,280 | Not Implemented |
NC0022 # 05 Y:1994 | 05 | 1994 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $145 | $500 | Not Implemented |
AM0209 # 01 Y:1994 | 01 | 1994 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,000 | $27,760 | Not Implemented |
AM0209 # 02 Y:1994 | 02 | 1994 | ADJUST BURNERS FOR EFFICIENT OPERATION | $1,890 | $540 | Implemented |
AM0209 # 03 Y:1994 | 03 | 1994 | INSTALL SKYLIGHTS | $955 | $1,300 | Implemented |
AM0209 # 04 Y:1994 | 04 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $437 | $280 | Implemented |
RU0160 # 01 Y:1992 | 01 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,237 | $12,750 | Implemented |
RU0160 # 02 Y:1992 | 02 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $707 | $322 | Implemented |
RU0160 # 03 Y:1992 | 03 | 1992 | COVER OPEN TANKS | $1,112 | $350 | Implemented |
RU0160 # 04 Y:1992 | 04 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,501 | $849 | Implemented |
RU0160 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $678 | $0 | Implemented |
RU0160 # 06 Y:1992 | 06 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $9,367 | $507 | Implemented |
RU0160 # 07 Y:1992 | 07 | 1992 | USE WASTE HEAT FROM HOT FLUE GASES TO GENERATE STEAM | $9,901 | $11,500 | Implemented |
MO0048 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $677 | $755 | Not Implemented |