Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
499
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0646 # 05 Y:1998 | 05 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $2,730 | $10,050 | Implemented |
GT0646 # 06 Y:1998 | 06 | 1998 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $1,230 | $400 | Implemented |
GT0646 # 07 Y:1998 | 07 | 1998 | MODIFY STARTUP/SHUTDOWN TIMES | $37,988 | $0 | Not Implemented |
GT0644 # 01 Y:1998 | 01 | 1998 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $303 | $0 | Implemented |
GT0644 # 02 Y:1998 | 02 | 1998 | COVER OPEN TANKS | $6,346 | $1,838 | Not Implemented |
GT0644 # 03 Y:1998 | 03 | 1998 | TURN OFF EQUIPMENT WHEN NOT IN USE | $6,251 | $0 | Implemented |
GT0644 # 04 Y:1998 | 04 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,049 | $5,558 | Not Implemented |
GT0644 # 05 Y:1998 | 05 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,160 | $750 | Implemented |
GT0644 # 06 Y:1998 | 06 | 1998 | CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS | $12,300 | $2,000 | Not Implemented |
GT0644 # 07 Y:1998 | 07 | 1998 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $21,400 | $32,860 | Not Implemented |
GT0644 # 08 Y:1998 | 08 | 1998 | FILTER AND REUSE HYDRAULIC OIL | $7,448 | $4,500 | Not Implemented |
GT0644 # 09 Y:1998 | 09 | 1998 | CONDENSE OPERATION INTO ONE BUILDING | $6,516 | $0 | Implemented |
GT0616 # 01 Y:1997 | 01 | 1997 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $21,160 | $0 | Not Implemented |
GT0616 # 02 Y:1997 | 02 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,600 | $18,500 | Implemented |
GT0616 # 03 Y:1997 | 03 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,385 | $0 | Implemented |
GT0616 # 04 Y:1997 | 04 | 1997 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $2,964 | $6,700 | Implemented |
GT0616 # 05 Y:1997 | 05 | 1997 | RECOVER AND REUSE WASTE MATERIAL | $230 | $0 | Implemented |
GT0624 # 01 Y:1997 | 01 | 1997 | LOWER LIGHT FIXTURES IN HIGH CEILING AREAS | $2,995 | $4,380 | Implemented |
GT0624 # 02 Y:1997 | 02 | 1997 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,420 | $900 | Implemented |
GT0624 # 03 Y:1997 | 03 | 1997 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,480 | $150 | Implemented |
GT0624 # 04 Y:1997 | 04 | 1997 | UPGRADE CONTROLS ON COMPRESSORS | $2,470 | $0 | Not Implemented |
GT0624 # 05 Y:1997 | 05 | 1997 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $80 | $250 | Not Implemented |
GT0624 # 06 Y:1997 | 06 | 1997 | CONVERT TO ELECTROSTATIC POWDER COATING | $6,540 | $0 | Not Implemented |
GT0624 # 07 Y:1997 | 07 | 1997 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $1,600 | $1,320 | Not Implemented |
GT0624 # 08 Y:1997 | 08 | 1997 | MODIFY PROCESS TO REDUCE MATERIAL USE/COST | $18,900 | $4,000 | Not Implemented |