Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

547

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
KU0466 # 10 Y:1996 10 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $387 $688 Implemented
KU0466 # 11 Y:1996 11 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $135 $119 Implemented
KU0463 # 01 Y:1996 01 1996 UTILIZE OTHER METHODS TO REMOVE CONTAMINANTS $24,383 $3,800 Not Implemented
KU0463 # 02 Y:1996 02 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,482 $284 Implemented
KU0463 # 03 Y:1996 03 1996 INSTALL OCCUPANCY SENSORS $1,237 $1,200 Not Implemented
KU0463 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $936 $2,112 Implemented
KU0463 # 05 Y:1996 05 1996 ADJUST BURNERS FOR EFFICIENT OPERATION $633 $1,000 Implemented
KU0463 # 06 Y:1996 06 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $482 $375 Not Implemented
KU0460 # 01 Y:1996 01 1996 CONVERT TO HIGH VOLUME LOW PRESSURE (HVLP) PAINT GUNS $38,846 $2,500 Implemented
KU0460 # 02 Y:1996 02 1996 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $6,108 $15,150 Implemented
KU0460 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,741 $20,119 Not Implemented
KU0460 # 04 Y:1996 04 1996 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,386 $5,807 Not Implemented
KU0460 # 05 Y:1996 05 1996 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,935 $375 Not Implemented
KU0460 # 06 Y:1996 06 1996 INSTALL OCCUPANCY SENSORS $1,272 $850 Not Implemented
KU0460 # 07 Y:1996 07 1996 CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE $183 $0 Not Implemented
KU0454 # 01 Y:1995 01 1995 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $28,987 $18,760 Implemented
KU0454 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $8,681 $10,200 Implemented
KU0454 # 03 Y:1995 03 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,625 $8,741 Implemented
KU0454 # 04 Y:1995 04 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,851 $5,940 Not Implemented
KU0454 # 05 Y:1995 05 1995 INSTALL OCCUPANCY SENSORS $2,037 $1,750 Not Implemented
KU0454 # 06 Y:1995 06 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $778 $1,140 Implemented
KU0454 # 07 Y:1995 07 1995 USE PHOTOCELL CONTROLS $548 $120 Implemented
KU0454 # 08 Y:1995 08 1995 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $737 $333 Not Implemented
KU0454 # 09 Y:1995 09 1995 RECOVER WASTE HEAT FROM EQUIPMENT $831 $865 Implemented
KU0454 # 10 Y:1995 10 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $157 $176 Implemented