Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15,265

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0484 # 08 Y:2014 08 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,298 $0 Implemented
WV0484 # 09 Y:2014 09 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,489 $6,113 Implemented
CO0683 # 01 Y:2014 01 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $16,540 $21,440 Not Implemented
CO0683 # 02 Y:2014 02 2014 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $12,750 $13,140 Not Implemented
CO0683 # 03 Y:2014 03 2014 USE COOLING TOWER OR ECONOMIZER TO REPLACE CHILLER COOLING $8,270 $0 Not Implemented
CO0683 # 04 Y:2014 04 2014 SHUT OFF COOLING IF COLD OUTSIDE AIR WILL COOL PROCESS $2,440 $6,450 Not Implemented
OK0871 # 01 Y:2014 01 2014 INSTALL SET-BACK TIMERS $1,092 $676 Implemented
OK0871 # 02 Y:2014 02 2014 CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS $774 $280 Implemented
OK0871 # 03 Y:2014 03 2014 REPLACE EXISTING HVAC UNIT WITH HIGH EFFICIENCY MODEL $2,523 $5,398 Not Implemented
OK0871 # 04 Y:2014 04 2014 INSTALL SET-BACK TIMERS $701 $2,100 Implemented
OK0871 # 05 Y:2014 05 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,148 $24,197 Not Implemented
OK0871 # 06 Y:2014 06 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,142 $3,353 Not Implemented
OK0871 # 07 Y:2014 07 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $507 $4,399 Not Implemented
OK0871 # 08 Y:2014 08 2014 USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES $2,956 $4,399 Implemented
OK0871 # 09 Y:2014 09 2014 RECOVER WASTE HEAT FROM EQUIPMENT $521 $689 Not Implemented
OK0871 # 10 Y:2014 10 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,242 $500 Implemented
OR0625 # 01 Y:2014 01 2014 TURN OFF EQUIPMENT WHEN NOT IN USE $11,654 $1,000 Not Implemented
OR0625 # 02 Y:2014 02 2014 UTILIZE A LESS EXPENSIVE COOLING METHOD $5,751 $5,908 Not Implemented
OR0625 # 03 Y:2014 03 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $3,834 $800 Not Implemented
OR0625 # 04 Y:2014 04 2014 USE SOLAR HEAT TO MAKE ELECTRICTY $5,889 $72,131 Not Implemented
OR0625 # 05 Y:2014 05 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $5,528 $0 Not Implemented
OR0625 # 06 Y:2014 06 2014 REDUCE FLUID FLOW RATES $2,097 $5,600 Not Implemented
BD0441 # 01 Y:2014 01 2014 REPAIR AND ELIMINATE STEAM LEAKS $3,813 $2,600 Implemented
BD0441 # 02 Y:2014 02 2014 INSTALL OCCUPANCY SENSORS $273 $450 Not Implemented
BD0441 # 03 Y:2014 03 2014 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $505 $20 Not Implemented