Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center | North Carolina State |
---|---|
Assessment Year | 2014 |
Principal Product | Air filters |
NAICS | 333413 - Industrial and Commercial Fan and Blower and Air Purification Equipment Manufacturing |
SIC | 3564 - Blowers And Fans |
Sales | $50,000,000-$100,000,000 |
# of Employees | 640 |
Plant Area (Sq.Ft.) | 521,523 |
Annual Production | 33,000,000 Pieces |
Production Hrs. Annual | 2,750 |
Location (State) | NC |
Source | Yearly Cost | Usage | Unit | Unit Cost |
---|---|---|---|---|
Electricity Usage | $275,917 | 5,237,297 | kWh | $0.05 |
Electricity Demand | $99,128 | 11,650 | kW-months/year | $8.51 |
Electricity Fees | $1,647 | - | $ | - |
TOTAL ENERGY COSTS | $376,692 | |||
RECOMMENDED SAVINGS* | $35,957 | *Non-energy impacts included in savings. See recommendations below |
||
IMPLEMENTED SAVINGS* | $9,402 |
#|Description |
Savings Cost |
Status | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|---|
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | ||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
01: 2.7241 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT |
Savings: $14,069 Cost: $54,000 |
$14,069 | 266,964 | - | - | - | - | - | - |
$14,069 266,964 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
02: 2.3135 SCHEDULE ROUTINE MAINTENANCE DURING NON-OPERATING PERIODS |
Savings: $1,055 Cost: - |
- | - | $1,055 | 124 | - | - | - | - |
- - kWh |
$1,055 124 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
03: 2.3132 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS |
Savings: $1,962 Cost: $200 |
$440 | - | $1,522 | 175 | - | - | - | - |
$440 - kWh |
$1,522 175 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
04: 2.4146 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM |
Savings: $4,946 Cost: $18,000 |
$4,946 | 93,844 | - | - | - | - | - | - |
$4,946 93,844 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
05: 2.4231 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED |
Savings: $2,542 Cost: $5,000 |
$1,888 | 35,818 | $654 | 77 | - | - | - | - |
$1,888 35,818 kWh |
$654 77 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
06: 2.4236 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES |
Savings: $443 Cost: $200 |
$594 | 11,280 | $209 | 24 | $(-200) | - | $(-160) | - |
$594 11,280 kWh |
$209 24 kW-months/year |
$(-200) - $ |
$(-160) - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
07: 2.4239 ELIMINATE OR REDUCE COMPRESSED AIR USAGE |
Savings: $1,767 Cost: $4,000 |
$534 | 10,141 | $1,233 | 145 | - | - | - | - |
$534 10,141 kWh |
$1,233 145 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
08: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $2,623 Cost: $2,350 |
$1,724 | 32,710 | $654 | 77 | - | - | $245 | - |
$1,724 32,710 kWh |
$654 77 kW-months/year |
- - $ |
$245 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
09: 2.7135 INSTALL OCCUPANCY SENSORS |
Savings: $2,127 Cost: $6,420 |
$2,127 | 40,364 | - | - | - | - | - | - |
$2,127 40,364 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
10: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS |
Savings: $686 Cost: $563 |
$425 | 8,064 | $147 | 17 | - | - | $114 | - |
$425 8,064 kWh |
$147 17 kW-months/year |
- - $ |
$114 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
11: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $632 Cost: $176 |
$248 | 4,702 | $55 | 6 | - | - | $329 | - |
$248 4,702 kWh |
$55 6 kW-months/year |
- - $ |
$329 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
12: 2.7134 USE PHOTOCELL CONTROLS |
Savings: $341 Cost: $80 |
$341 | 6,480 | - | - | - | - | - | - |
$341 6,480 kWh |
- - kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
13: 2.7142 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS |
Savings: $763 Cost: $2,400 |
$528 | 10,021 | $235 | 27 | - | - | - | - |
$528 10,021 kWh |
$235 27 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
14: 2.4151 DEVELOP A REPAIR/REPLACE POLICY |
Savings: $2,001 Cost: $4,256 |
$1,487 | 28,207 | $514 | 60 | - | - | - | - |
$1,487 28,207 kWh |
$514 60 kW-months/year |
- - $ |
- - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL RECOMMENDED |
Savings: $35,957 Cost: $97,645 |
$29,351 | 548,595 | $6,278 | 732 | $(-200) | - | $528 | - | $29,351 548,595 kWh |
$6,278 732 kW-months/year |
$(-200) - $ |
$528 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
TOTAL IMPLEMENTED |
Savings: $9,402 Cost: $7,745 |
$4,918 | 84,963 | $4,156 | 483 | $(-200) | - | $528 | - | $4,918 84,963 kWh |
$4,156 483 kW-months/year |
$(-200) - $ |
$528 - $ |
||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Savings Cost |
$ | kWh | $ | kW-months/year | $ | $ | $ | $ | |||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||||
Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost | Electricity Usage | Electricity Demand | Personnel Changes | Ancillary Material Cost |