Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
505
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
CO0180 # 04 Y:1990 | 04 | 1990 | CLEAN AND MAINTAIN REFRIGERANT CONDENSERS AND TOWERS | $1,920 | $3,400 | Not Implemented |
CO0180 # 05 Y:1990 | 05 | 1990 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $1,180 | $2,700 | Not Implemented |
CO0180 # 06 Y:1990 | 06 | 1990 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $850 | $500 | Implemented |
CO0180 # 07 Y:1990 | 07 | 1990 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $240 | $400 | Implemented |
CO0180 # 08 Y:1990 | 08 | 1990 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $116 | $128 | Implemented |
CO0156 # 01 Y:1989 | 01 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,970 | $250 | Implemented |
CO0156 # 02 Y:1989 | 02 | 1989 | REVISE SMOKE CLEANUP FROM OPERATIONS | $1,120 | $3,500 | Not Implemented |
CO0156 # 03 Y:1989 | 03 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,480 | $1,200 | Implemented |
CO0156 # 04 Y:1989 | 04 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $4,640 | $1,500 | Implemented |
CO0156 # 05 Y:1989 | 05 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,240 | $800 | Implemented |
CO0156 # 06 Y:1989 | 06 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $277 | $105 | Implemented |
CO0156 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $635 | $2,480 | Implemented |
CO0156 # 08 Y:1989 | 08 | 1989 | USE SEPARATE SWITCHES ON PERIMETER LIGHTING WHICH MAY BE TURNED OFF WHEN NATURAL LIGHT IS AVAILABLE | $1,470 | $1,800 | Not Implemented |
CO0156 # 09 Y:1989 | 09 | 1989 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $2,131 | $5,000 | Not Implemented |
CO0156 # 10 Y:1989 | 10 | 1989 | INSULATE BARE EQUIPMENT | $660 | $500 | Not Implemented |
CO0149 # 01 Y:1989 | 01 | 1989 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $2,830 | $1,200 | Implemented |
CO0149 # 02 Y:1989 | 02 | 1989 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,014 | $400 | Implemented |
CO0149 # 03 Y:1989 | 03 | 1989 | RECOVER WASTE HEAT FROM EQUIPMENT | $330 | $500 | Implemented |
CO0149 # 04 Y:1989 | 04 | 1989 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $430 | $200 | Implemented |
CO0149 # 05 Y:1989 | 05 | 1989 | INSTALL TIMERS AND/OR THERMOSTATS | $3,260 | $1,000 | Implemented |
CO0149 # 06 Y:1989 | 06 | 1989 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $1,325 | $100 | Implemented |
CO0149 # 07 Y:1989 | 07 | 1989 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $417 | $900 | Implemented |
CO0149 # 08 Y:1989 | 08 | 1989 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $840 | $300 | Implemented |
CO0137 # 01 Y:1988 | 01 | 1988 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $1,200 | $500 | Implemented |
CO0137 # 02 Y:1988 | 02 | 1988 | OPTIMIZE PLANT POWER FACTOR | $4,000 | $5,850 | Implemented |