Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

540

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0360 # 03 Y:1991 03 1991 RECOVER WASTE HEAT FROM EQUIPMENT $2,917 $1,000 Implemented
KU0350 # 01 Y:1991 01 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $36,079 $0 Implemented
KU0350 # 02 Y:1991 02 1991 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $1,101 $12,000 Implemented
KU0350 # 03 Y:1991 03 1991 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $6,192 $7,440 Implemented
KU0350 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $995 $550 Implemented
KU0350 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $550 $950 Implemented
KU0350 # 06 Y:1991 06 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,198 $1,230 Implemented
KU0350 # 07 Y:1991 07 1991 RECOVER WASTE HEAT FROM EQUIPMENT $692 $450 Implemented
KU0350 # 08 Y:1991 08 1991 COVER OPEN TANKS $212 $350 Implemented
KU0340 # 01 Y:1991 01 1991 INSTALL TIMERS AND/OR THERMOSTATS $8,570 $0 Not Implemented
KU0340 # 02 Y:1991 02 1991 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $7,689 $200 Not Implemented
KU0340 # 03 Y:1991 03 1991 REDUCE VENTILATION AIR $6,174 $100 Not Implemented
KU0340 # 04 Y:1991 04 1991 REDUCE VENTILATION AIR $1,042 $350 Not Implemented
KU0340 # 05 Y:1991 05 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $5,351 $900 Not Implemented
KU0340 # 06 Y:1991 06 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $174 $0 Not Implemented
KU0342 # 01 Y:1991 01 1991 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $12,017 $3,600 Not Implemented
KU0342 # 02 Y:1991 02 1991 INSTALL TIMERS AND/OR THERMOSTATS $8,091 $9,690 Not Implemented
KU0342 # 03 Y:1991 03 1991 INSTALL TIMERS AND/OR THERMOSTATS $774 $1,140 Not Implemented
KU0342 # 04 Y:1991 04 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $7,753 $500 Not Implemented
KU0342 # 05 Y:1991 05 1991 DE-ENERGIZE EXCESS TRANSFORMER CAPACITY $4,942 $100,000 Not Implemented
KU0342 # 06 Y:1991 06 1991 INSTALL SET-BACK TIMERS $2,678 $550 Not Implemented
KU0342 # 07 Y:1991 07 1991 REDUCE VENTILATION AIR $1,195 $200 Not Implemented
KU0342 # 08 Y:1991 08 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $325 $0 Not Implemented
KU0339 # 01 Y:1991 01 1991 CENTRALIZE CONTROL OF EXHAUST FANS TO ENSURE THEIR SHUTDOWN, OR ESTABLISH PROGRAM TO ENSURE MANUAL SHUTDOWN $4,004 $700 Implemented
KU0339 # 02 Y:1991 02 1991 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,315 $1,860 Implemented