Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,265
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0456 # 09 Y:2012 | 09 | 2012 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $3,207 | $5,050 | Not Implemented |
WV0456 # 10 Y:2012 | 10 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,040 | $2,069 | Implemented |
WV0456 # 11 Y:2012 | 11 | 2012 | IMPROVE LUBRICATION PRACTICES | $1,660 | $1,000 | Implemented |
WV0456 # 12 Y:2012 | 12 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,637 | $2,475 | Implemented |
WV0456 # 13 Y:2012 | 13 | 2012 | VENTILATION SYSTEM TO SHUT OFF WHEN ROOM IS NOT IN USE | $1,180 | $1,000 | Implemented |
WV0456 # 14 Y:2012 | 14 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,129 | $555 | Implemented |
WV0456 # 15 Y:2012 | 15 | 2012 | DEVELOP A REPAIR/REPLACE POLICY | $1,089 | $981 | Implemented |
WV0456 # 16 Y:2012 | 16 | 2012 | USE PHOTOCELL CONTROLS | $824 | $705 | Implemented |
MZ0097 # 01 Y:2012 | 01 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $230,479 | $107,601 | Not Implemented |
MZ0097 # 02 Y:2012 | 02 | 2012 | INSULATE BARE EQUIPMENT | $106,168 | $10,690 | Not Implemented |
MZ0097 # 03 Y:2012 | 03 | 2012 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $60,715 | $105,000 | Not Implemented |
MZ0097 # 04 Y:2012 | 04 | 2012 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $49,961 | $5,000 | Not Implemented |
MZ0097 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $29,305 | $35,000 | Implemented |
MZ0097 # 06 Y:2012 | 06 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,968 | $450 | Implemented |
MZ0097 # 07 Y:2012 | 07 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,420 | $2,000 | Not Implemented |
SU0324 # 01 Y:2012 | 01 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $3,908 | $0 | Implemented |
SU0324 # 02 Y:2012 | 02 | 2012 | UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED | $1,326 | $0 | Implemented |
SU0324 # 03 Y:2012 | 03 | 2012 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $952 | $0 | Implemented |
SU0324 # 04 Y:2012 | 04 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $820 | $280 | Implemented |
SU0324 # 05 Y:2012 | 05 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $4,357 | $5,371 | Not Implemented |
SU0324 # 06 Y:2012 | 06 | 2012 | CONSERVE ENERGY BY EFFICIENT USE OF VENDING MACHINES | $426 | $777 | Not Implemented |
SU0324 # 07 Y:2012 | 07 | 2012 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,282 | $6,008 | Implemented |
SU0324 # 08 Y:2012 | 08 | 2012 | USE OTHER WASTE CONCENTRATION METHODS | $5,924 | $18,000 | Not Implemented |
WV0454 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,085 | $108,401 | Not Implemented |
WV0454 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,088 | $7,920 | Not Implemented |