Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

549

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
IA0107 # 05 Y:1995 05 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,094 $20 Not Implemented
IA0107 # 06 Y:1995 06 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $525 $149 Implemented
IA0096 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $11,198 $350 Implemented
IA0096 # 02 Y:1994 02 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,811 $365 Not Implemented
IA0096 # 03 Y:1994 03 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $1,098 $25 Not Implemented
IA0096 # 04 Y:1994 04 1994 COVER OPEN TANKS $1,597 $3,050 Not Implemented
IA0096 # 05 Y:1994 05 1994 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $6,971 $0 Not Implemented
IA0096 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,536 $7,244 Implemented
IA0096 # 07 Y:1994 07 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $522 $771 Not Implemented
IA0096 # 08 Y:1994 08 1994 INSTALL OCCUPANCY SENSORS $448 $1,067 Implemented
IA0088 # 01 Y:1994 01 1994 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $19,839 $32,340 Not Implemented
IA0088 # 02 Y:1994 02 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,944 $400 Implemented
IA0088 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,089 $800 Implemented
IA0088 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $1,958 $1,905 Implemented
IA0088 # 05 Y:1994 05 1994 USE PHOTOCELL CONTROLS $652 $1,050 Not Implemented
IA0088 # 06 Y:1994 06 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $547 $5,083 Not Implemented
IA0088 # 07 Y:1994 07 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $219 $56 Implemented
IA0078 # 01 Y:1994 01 1994 ADD AREA LIGHTING SWITCHES $7,178 $900 Implemented
IA0078 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,127 $1,227 Implemented
IA0078 # 03 Y:1994 03 1994 DISCONNECT BALLASTS $1,359 $983 Implemented
IA0078 # 04 Y:1994 04 1994 INSTALL OCCUPANCY SENSORS $1,226 $2,371 Implemented
IA0078 # 05 Y:1994 05 1994 REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS $7,527 $0 Not Implemented
IA0078 # 06 Y:1994 06 1994 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $3,695 $0 Implemented
IA0078 # 07 Y:1994 07 1994 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,352 $2,218 Not Implemented
IA0078 # 08 Y:1994 08 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $669 $25 Not Implemented