IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15,265

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
SF0036 # 03 Y:1994 03 1994 INSTALL OCCUPANCY SENSORS $1,751 $4,080 Not Implemented
SF0036 # 04 Y:1994 04 1994 TURN OFF EQUIPMENT WHEN NOT IN USE $1,893 $3,880 Implemented
SF0036 # 05 Y:1994 05 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $3,020 $40 Implemented
SF0036 # 06 Y:1994 06 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $3,557 $1,457 Not Implemented
SF0036 # 07 Y:1994 07 1994 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $5,419 $7,395 Not Implemented
UD0440 # 01 Y:1994 01 1994 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $7,448 $0 n/a
UD0440 # 02 Y:1994 02 1994 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $8,640 $250 n/a
UD0440 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $10,786 $3,000 n/a
UD0440 # 04 Y:1994 04 1994 ADD AREA LIGHTING SWITCHES $2,496 $200 n/a
UD0440 # 05 Y:1994 05 1994 ADD AREA LIGHTING SWITCHES $1,454 $200 n/a
WV0045 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $530 $740 Implemented
WV0045 # 02 Y:1994 02 1994 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $2,284 $960 Not Implemented
WV0045 # 03 Y:1994 03 1994 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $4,030 $4,400 Not Implemented
WV0045 # 04 Y:1994 04 1994 UTILIZE CONTROLS TO OPERATE EQUIPMENT ONLY WHEN NEEDED $2,270 $960 Implemented
WV0045 # 05 Y:1994 05 1994 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $960 $18 Implemented
WV0045 # 06 Y:1994 06 1994 USE SYNTHETIC LUBRICANT $156 $0 Not Implemented
WV0045 # 07 Y:1994 07 1994 INSTALL TIMERS AND/OR THERMOSTATS $1,511 $900 Implemented
WV0042 # 01 Y:1994 01 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,279 $7,375 Implemented
WV0042 # 02 Y:1994 02 1994 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,921 $0 Not Implemented
WV0042 # 03 Y:1994 03 1994 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $2,094 $1,372 Implemented
WV0042 # 04 Y:1994 04 1994 RECOVER WASTE HEAT FROM EQUIPMENT $3,973 $440 Not Implemented
WV0042 # 05 Y:1994 05 1994 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $3,391 $4,400 Not Implemented
WV0042 # 06 Y:1994 06 1994 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $11,021 $6,660 Not Implemented
WV0042 # 07 Y:1994 07 1994 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $340 $200 Implemented
WV0042 # 08 Y:1994 08 1994 USE SYNTHETIC LUBRICANT $2,246 $0 Not Implemented