Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,260
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0051 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $841 | $1,015 | Implemented |
MO0051 # 03 Y:1992 | 03 | 1992 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $17,413 | $0 | Not Implemented |
MO0051 # 04 Y:1992 | 04 | 1992 | INSTALL STORM WINDOWS AND DOORS | $13,673 | $5,500 | Not Implemented |
MO0051 # 05 Y:1992 | 05 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $456 | $60 | Not Implemented |
MO0051 # 06 Y:1992 | 06 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,681 | $2,200 | Implemented |
MO0051 # 07 Y:1992 | 07 | 1992 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $43 | $110 | Implemented |
MO0051 # 08 Y:1992 | 08 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $257 | $1,011 | Not Implemented |
MO0051 # 09 Y:1992 | 09 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,200 | $240 | Implemented |
MO0051 # 10 Y:1992 | 10 | 1992 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $479 | $0 | Implemented |
KU0365 # 01 Y:1992 | 01 | 1992 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $13,442 | $0 | Not Implemented |
KU0365 # 02 Y:1992 | 02 | 1992 | USE "HEAT WHEEL" OR OTHER HEAT EXCHANGER TO CROSS-EXCHANGE BUILDING EXHAUST AIR WITH MAKE-UP AIR | $6,266 | $31,766 | Implemented |
KU0365 # 03 Y:1992 | 03 | 1992 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,768 | $887 | Implemented |
KU0365 # 04 Y:1992 | 04 | 1992 | INSTALL SET-BACK TIMERS | $873 | $870 | Not Implemented |
KU0365 # 05 Y:1992 | 05 | 1992 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,302 | $540 | Implemented |
KU0365 # 06 Y:1992 | 06 | 1992 | RECOVER WASTE HEAT FROM EQUIPMENT | $400 | $900 | Not Implemented |
KU0365 # 07 Y:1992 | 07 | 1992 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $397 | $250 | Implemented |
KU0365 # 08 Y:1992 | 08 | 1992 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $254 | $160 | Not Implemented |
SD0017 # 01 Y:1992 | 01 | 1992 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $422 | $527 | Implemented |
SD0017 # 02 Y:1992 | 02 | 1992 | INSULATE BARE EQUIPMENT | $77 | $214 | Not Implemented |
SD0017 # 03 Y:1992 | 03 | 1992 | KEEP LAMPS AND REFLECTORS CLEAN | $9,331 | $15,354 | Implemented |
SD0017 # 04 Y:1992 | 04 | 1992 | USE COMPUTER PROGRAMS TO OPTIMIZE HVAC PERFORMANCE | $2,621 | $400 | Not Implemented |
ND0018 # 01 Y:1992 | 01 | 1992 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $21,576 | $62,547 | Not Implemented |
ND0018 # 02 Y:1992 | 02 | 1992 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,520 | $0 | Not Implemented |
ND0018 # 03 Y:1992 | 03 | 1992 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $3,149 | $400 | Not Implemented |
ND0018 # 04 Y:1992 | 04 | 1992 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,895 | $0 | Not Implemented |