Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

15,114

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0335 # 03 Y:1991 03 1991 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $3,524 $2,000 Implemented
UD0335 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,026 $0 Implemented
AM0110 # 01 Y:1991 01 1991 OPTIMIZE PLANT POWER FACTOR $1,260 $5,180 Not Implemented
AM0110 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $510 $750 Not Implemented
AM0110 # 03 Y:1991 03 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $131 $105 Not Implemented
AM0110 # 04 Y:1991 04 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $315 $52 Not Implemented
AM0110 # 05 Y:1991 05 1991 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $240 $100 Not Implemented
AM0110 # 06 Y:1991 06 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $200 $160 Not Implemented
AM0110 # 07 Y:1991 07 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $85 $0 Not Implemented
AM0106 # 01 Y:1991 01 1991 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $6,600 $24,750 Not Implemented
AM0106 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $221 $144 Not Implemented
AM0106 # 03 Y:1991 03 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $375 $500 Not Implemented
AM0106 # 04 Y:1991 04 1991 INSTALL SET-BACK TIMERS $198 $260 Not Implemented
AM0106 # 05 Y:1991 05 1991 INSTALL TIMERS AND/OR THERMOSTATS $127 $260 Not Implemented
AM0106 # 06 Y:1991 06 1991 USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD $80 $0 Not Implemented
CO0202 # 01 Y:1991 01 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,100 $700 Implemented
CO0202 # 02 Y:1991 02 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $551 $1,625 Implemented
CO0202 # 03 Y:1991 03 1991 INSTALL TIMERS AND/OR THERMOSTATS $550 $1,500 Implemented
CO0202 # 04 Y:1991 04 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,533 $1,100 Implemented
UD0330 # 01 Y:1990 01 1990 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $1,879 $0 Not Implemented
UD0330 # 02 Y:1990 02 1990 RECOVER AND REUSE COOLING WATER $8,744 $10,000 Not Implemented
UD0330 # 03 Y:1990 03 1990 RECOVER WASTE HEAT FROM EQUIPMENT $8,017 $15,000 Implemented
UD0330 # 04 Y:1990 04 1990 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $3,681 $500 Not Implemented
UD0330 # 05 Y:1990 05 1990 INSTALL SET-BACK TIMERS $5,716 $1,500 Not Implemented
AS0015 # 01 Y:1990 01 1990 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $18,956 $1,000 Implemented