Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
15,260
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
OK0188 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,423 | $1,120 | Not Implemented |
OK0188 # 05 Y:1986 | 05 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,358 | $11,320 | Implemented |
OK0190 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,326 | $229 | Implemented |
OK0190 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $706 | $80 | Implemented |
OK0190 # 03 Y:1986 | 03 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $5,318 | $0 | Implemented |
OK0190 # 04 Y:1986 | 04 | 1986 | OPTIMIZE PLANT POWER FACTOR | $4,159 | $12,400 | Not Implemented |
OK0190 # 05 Y:1986 | 05 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $388 | $1,600 | Not Implemented |
OK0190 # 06 Y:1986 | 06 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $9,381 | $0 | Not Implemented |
OK0191 # 01 Y:1986 | 01 | 1986 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $643 | $0 | Implemented |
OK0191 # 02 Y:1986 | 02 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $721 | $200 | Implemented |
OK0191 # 03 Y:1986 | 03 | 1986 | INSULATE BARE EQUIPMENT | $224 | $92 | Implemented |
OK0191 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $349 | $510 | Not Implemented |
OK0191 # 05 Y:1986 | 05 | 1986 | USE RADIANT HEATER FOR SPOT HEATING | $2,051 | $7,950 | Not Implemented |
KU0195 # 01 Y:1986 | 01 | 1986 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,653 | $139 | Not Implemented |
KU0195 # 02 Y:1986 | 02 | 1986 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,374 | $14 | Implemented |
KU0195 # 03 Y:1986 | 03 | 1986 | REDUCE VENTILATION AIR | $756 | $100 | Not Implemented |
KU0195 # 04 Y:1986 | 04 | 1986 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,705 | $0 | Implemented |
KU0195 # 05 Y:1986 | 05 | 1986 | INSTALL TIMERS AND/OR THERMOSTATS | $4,203 | $106 | Implemented |
KU0195 # 06 Y:1986 | 06 | 1986 | INSTALL SET-BACK TIMERS | $1,360 | $222 | Implemented |
KU0195 # 07 Y:1986 | 07 | 1986 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $964 | $600 | Implemented |
KU0195 # 08 Y:1986 | 08 | 1986 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $148 | $200 | Implemented |
KU0195 # 09 Y:1986 | 09 | 1986 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $124 | $200 | Implemented |
KU0195 # 10 Y:1986 | 10 | 1986 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $229 | $0 | Implemented |
KU0195 # 11 Y:1986 | 11 | 1986 | INSTALL AUTOMATIC STACK DAMPER | $456 | $700 | Implemented |