Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
159
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0442 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $179 | $325 | Implemented |
KU0442 # 07 Y:1994 | 07 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,066 | $9,950 | Implemented |
KU0442 # 08 Y:1994 | 08 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,058 | $2,075 | Implemented |
KU0442 # 09 Y:1994 | 09 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,195 | $8,640 | Implemented |
KU0442 # 10 Y:1994 | 10 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $435 | $400 | Implemented |
KU0442 # 11 Y:1994 | 11 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $271 | $130 | Implemented |
IA0085 # 01 Y:1994 | 01 | 1994 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $26,882 | $250 | Implemented |
IA0085 # 02 Y:1994 | 02 | 1994 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $11,787 | $17,070 | Implemented |
IA0085 # 03 Y:1994 | 03 | 1994 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $6,923 | $24,300 | Implemented |
IA0085 # 04 Y:1994 | 04 | 1994 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,137 | $550 | Not Implemented |
IA0085 # 05 Y:1994 | 05 | 1994 | INSTALL OCCUPANCY SENSORS | $1,290 | $2,114 | Implemented |
IA0085 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,016 | $137 | Implemented |
IA0085 # 07 Y:1994 | 07 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $463 | $375 | Not Implemented |
KU0232 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,464 | $0 | Implemented |
KU0232 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $576 | $366 | Not Implemented |
KU0232 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $572 | $100 | Implemented |
KU0232 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $170 | $0 | Implemented |
KU0232 # 05 Y:1987 | 05 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $158 | $40 | Implemented |
KU0232 # 06 Y:1987 | 06 | 1987 | IMPROVE LUBRICATION PRACTICES | $134 | $0 | Not Implemented |
CO0089 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,416 | $21 | Implemented |
CO0089 # 02 Y:1987 | 02 | 1987 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,026 | $150 | Implemented |
CO0089 # 03 Y:1987 | 03 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,537 | $500 | Implemented |
CO0089 # 04 Y:1987 | 04 | 1987 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $8,540 | $3,000 | Not Implemented |
CO0089 # 05 Y:1987 | 05 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $726 | $300 | Implemented |
CO0089 # 06 Y:1987 | 06 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $13,198 | $0 | Implemented |