Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

442

matching recommendations
Reset
SIC 35 Industrial Machinery And Equipment
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
AS0091 # 05 Y:1993 05 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $223 $500 Not Implemented
AS0091 # 06 Y:1993 06 1993 USE SYNTHETIC LUBRICANT $95 $0 Not Implemented
AS0091 # 07 Y:1993 07 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,223 $2,074 Not Implemented
AS0091 # 08 Y:1993 08 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,767 $4,293 Not Implemented
AS0091 # 09 Y:1993 09 1993 INSTALL OCCUPANCY SENSORS $3,014 $0 Not Implemented
AS0091 # 10 Y:1993 10 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $421 $340 Not Implemented
IA0057 # 01 Y:1993 01 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $3,530 $433 Implemented
IA0057 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,451 $2,374 Implemented
IA0057 # 03 Y:1993 03 1993 INSTALL OCCUPANCY SENSORS $931 $2,367 Implemented
IA0057 # 04 Y:1993 04 1993 COVER OPEN TANKS $533 $375 Implemented
IA0057 # 05 Y:1993 05 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $154 $380 Not Implemented
ND0163 # 01 Y:1993 01 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $7,887 $2,004 n/a
ND0163 # 02 Y:1993 02 1993 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $372 $324 n/a
ND0163 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $314 $300 n/a
ND0163 # 04 Y:1993 04 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $671 $3,880 n/a
AM0186 # 01 Y:1993 01 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $272,040 $100,000 Not Implemented
AM0186 # 02 Y:1993 02 1993 TURN OFF EQUIPMENT WHEN NOT IN USE $33,670 $0 Implemented
AM0186 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $17,400 $68,000 Not Implemented
AM0186 # 04 Y:1993 04 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $17,300 $0 Not Implemented
AM0186 # 05 Y:1993 05 1993 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $7,460 $0 Implemented
AM0186 # 06 Y:1993 06 1993 SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY $5,540 $2,000 Not Implemented
OK0411 # 01 Y:1993 01 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,179 $946 Implemented
OK0411 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $211 $174 Implemented
OK0411 # 03 Y:1993 03 1993 OPTIMIZE PLANT POWER FACTOR $2,790 $3,332 Not Implemented
OK0411 # 04 Y:1993 04 1993 USE PLANT OWNED TRANSFORMERS OR LEASE TRANSFORMERS $76,619 $177,000 Not Implemented