Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
579
matching recommendationsSIC | 35 | Industrial Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
ME0234 # 10 Y:1998 | 10 | 1998 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $1,114 | $7,000 | Implemented |
ME0234 # 02 Y:1998 | 02 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $19,979 | $12,932 | Implemented |
ME0234 # 07 Y:1998 | 07 | 1998 | RECOVER AND REUSE COOLING WATER | $12,512 | $12,000 | Implemented |
ME0234 # 08 Y:1998 | 08 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $150 | $0 | Not Implemented |
ME0234 # 09 Y:1998 | 09 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,887 | $3,000 | Not Implemented |
ME0234 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $8,153 | $10,580 | Implemented |
ME0234 # 05 Y:1998 | 05 | 1998 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,284 | $800 | Implemented |
ME0234 # 06 Y:1998 | 06 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $975 | $500 | Implemented |
ME0234 # 01 Y:1998 | 01 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $38,400 | $50,000 | Implemented |
ME0234 # 04 Y:1998 | 04 | 1998 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $4,482 | $4,476 | Implemented |
UL0211 # 02 Y:1998 | 02 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $6,350 | $0 | n/a |
UL0211 # 01 Y:1998 | 01 | 1998 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $11,780 | $0 | n/a |
UL0211 # 03 Y:1998 | 03 | 1998 | ELIMINATE OLD STOCK AND MODIFY INVENTORY CONTROL | $6,169 | $15,000 | n/a |
GT0654 # 08 Y:1998 | 08 | 1998 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $3,740 | $5,000 | Implemented |
GT0654 # 06 Y:1998 | 06 | 1998 | PAY UTILITY BILLS ON TIME | $1,330 | $0 | Implemented |
GT0654 # 03 Y:1998 | 03 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $170 | $108 | Not Implemented |
GT0654 # 04 Y:1998 | 04 | 1998 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $737 | $150 | Implemented |
GT0654 # 02 Y:1998 | 02 | 1998 | INSTALL OCCUPANCY SENSORS | $150 | $52 | Not Implemented |
GT0654 # 01 Y:1998 | 01 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,734 | $12,757 | Not Implemented |
GT0654 # 05 Y:1998 | 05 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $200 | $0 | Implemented |
GT0654 # 07 Y:1998 | 07 | 1998 | MINIMIZE WATER USAGE | $935 | $1,100 | Not Implemented |
OK0560 # 04 Y:1998 | 04 | 1998 | CONVERT COMBUSTION EQUIPMENT TO BURN NATURAL GAS | $6,750 | $59,000 | Not Implemented |
OK0560 # 05 Y:1998 | 05 | 1998 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $23,508 | $27,000 | Not Implemented |
OK0560 # 07 Y:1998 | 07 | 1998 | LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER | $7,882 | $0 | Not Implemented |
OK0560 # 06 Y:1998 | 06 | 1998 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,039 | $7,452 | Implemented |