Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
75
matching recommendationsSIC | 352 | Farm And Garden Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0442 # 07 Y:1994 | 07 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $2,066 | $9,950 | Implemented |
KU0442 # 09 Y:1994 | 09 | 1994 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,195 | $8,640 | Implemented |
KU0442 # 10 Y:1994 | 10 | 1994 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $435 | $400 | Implemented |
KU0442 # 11 Y:1994 | 11 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $271 | $130 | Implemented |
KU0232 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,464 | $0 | Implemented |
KU0232 # 02 Y:1987 | 02 | 1987 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $576 | $366 | Not Implemented |
KU0232 # 03 Y:1987 | 03 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $572 | $100 | Implemented |
KU0232 # 04 Y:1987 | 04 | 1987 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $170 | $0 | Implemented |
KU0232 # 05 Y:1987 | 05 | 1987 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $158 | $40 | Implemented |
KU0232 # 06 Y:1987 | 06 | 1987 | IMPROVE LUBRICATION PRACTICES | $134 | $0 | Not Implemented |
CO0089 # 15 Y:1987 | 15 | 1987 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $479 | $300 | Implemented |
CO0089 # 14 Y:1987 | 14 | 1987 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,473 | $750 | Implemented |
CO0089 # 13 Y:1987 | 13 | 1987 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,437 | $1,000 | Implemented |
CO0089 # 12 Y:1987 | 12 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $3,066 | $750 | Implemented |
CO0089 # 11 Y:1987 | 11 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,916 | $13,440 | Not Implemented |
CO0089 # 10 Y:1987 | 10 | 1987 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $3,042 | $7,140 | Not Implemented |
CO0089 # 09 Y:1987 | 09 | 1987 | AIR CONDITION ONLY SPACE NECESSARY | $8,911 | $2,100 | Not Implemented |
CO0089 # 08 Y:1987 | 08 | 1987 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $19,113 | $24,000 | Implemented |
CO0089 # 07 Y:1987 | 07 | 1987 | USE RADIANT HEATER FOR SPOT HEATING | $50,245 | $180,000 | Not Implemented |
CO0089 # 06 Y:1987 | 06 | 1987 | INSTALL TIMERS AND/OR THERMOSTATS | $13,198 | $0 | Implemented |
CO0089 # 05 Y:1987 | 05 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $726 | $300 | Implemented |
CO0089 # 04 Y:1987 | 04 | 1987 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $8,540 | $3,000 | Not Implemented |
CO0089 # 03 Y:1987 | 03 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $6,537 | $500 | Implemented |
CO0089 # 02 Y:1987 | 02 | 1987 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $2,026 | $150 | Implemented |
CO0089 # 01 Y:1987 | 01 | 1987 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,416 | $21 | Implemented |