Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
864
matching recommendationsSIC | 352 | Farm And Garden Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0047 # 01 Y:2014 | 01 | 2014 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $19,205 | $13,000 | Implemented |
WM0047 # 02 Y:2014 | 02 | 2014 | USE SYNTHETIC LUBRICANT | $16,363 | $3,379 | Not Implemented |
WM0047 # 03 Y:2014 | 03 | 2014 | REPLACE BOILER | $18,181 | $49,000 | Not Implemented |
WM0047 # 04 Y:2014 | 04 | 2014 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $4,970 | $0 | Implemented |
WM0047 # 05 Y:2014 | 05 | 2014 | REDUCE FLUID FLOW RATES | $11,396 | $1,567 | Not Implemented |
WM0047 # 06 Y:2014 | 06 | 2014 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $1,884 | $0 | Not Implemented |
WM0047 # 07 Y:2014 | 07 | 2014 | UPGRADE CONTROLS ON COMPRESSORS | $2,925 | $5,500 | Not Implemented |
WM0047 # 08 Y:2014 | 08 | 2014 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $2,510 | $3,628 | Not Implemented |
WM0047 # 09 Y:2014 | 09 | 2014 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,932 | $2,100 | Implemented |
WM0047 # 10 Y:2014 | 10 | 2014 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,430 | $1,180 | Implemented |
UA0099 # 01 Y:2013 | 01 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $109,678 | $164,833 | Not Implemented |
UA0099 # 02 Y:2013 | 02 | 2013 | DISCONNECT BALLASTS | $3,632 | $242 | Not Implemented |
UA0099 # 03 Y:2013 | 03 | 2013 | USE RADIANT HEATER FOR SPOT HEATING | $25,020 | $52,360 | Not Implemented |
UA0099 # 04 Y:2013 | 04 | 2013 | OPTIMIZE PLANT POWER FACTOR | $19,434 | $14,980 | Not Implemented |
UA0099 # 05 Y:2013 | 05 | 2013 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $12,301 | $5,000 | Implemented |
UA0099 # 06 Y:2013 | 06 | 2013 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,883 | $400 | Not Implemented |
IA0487 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $17,612 | $72,410 | Implemented |
IA0487 # 02 Y:2012 | 02 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,511 | $19,201 | Implemented |
IA0487 # 03 Y:2012 | 03 | 2012 | INSTALL OCCUPANCY SENSORS | $3,110 | $6,400 | Not Implemented |
IA0487 # 04 Y:2012 | 04 | 2012 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $856 | $331 | Implemented |
IA0487 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $398 | $250 | Not Implemented |
IA0487 # 06 Y:2012 | 06 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $2,490 | $6,000 | Implemented |
IA0487 # 07 Y:2012 | 07 | 2012 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,650 | $35 | Implemented |
WV0454 # 01 Y:2012 | 01 | 2012 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $20,085 | $108,401 | Not Implemented |
WV0454 # 02 Y:2012 | 02 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $5,088 | $7,920 | Not Implemented |