Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
636
matching recommendationsSIC | 3523 | Farm Machinery And Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0765 # 10 Y:2007 | 10 | 2007 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $496 | $0 | Implemented |
UD0765 # 11 Y:2007 | 11 | 2007 | INSTALL SKYLIGHTS | $354 | $1,083 | Implemented |
UD0765 # 12 Y:2007 | 12 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $233 | $500 | Implemented |
UD0765 # 13 Y:2007 | 13 | 2007 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $216 | $324 | Implemented |
WI0523 # 06 Y:2006 | 06 | 2006 | USE SYNTHETIC LUBRICANT | $1,970 | $0 | Implemented |
WI0523 # 05 Y:2006 | 05 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $2,735 | $800 | Not Implemented |
WI0523 # 04 Y:2006 | 04 | 2006 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $3,880 | $0 | Not Implemented |
WI0523 # 03 Y:2006 | 03 | 2006 | RECOVER WASTE HEAT FROM EQUIPMENT | $5,347 | $1,000 | Implemented |
WI0523 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $27,911 | $52,320 | Not Implemented |
WI0523 # 01 Y:2006 | 01 | 2006 | IMPROVE SPACE COMFORT CONDITIONING | $58,800 | $3,000 | Not Implemented |
IA0391 # 01 Y:2006 | 01 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,991 | $410 | Implemented |
IA0391 # 02 Y:2006 | 02 | 2006 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $186 | $198 | Not Implemented |
IA0391 # 03 Y:2006 | 03 | 2006 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $136 | $89 | Implemented |
IA0391 # 04 Y:2006 | 04 | 2006 | ELIMINATE COOLING OF PROCESS STREAMS WHICH SUBSEQUENTLY MUST BE HEATED AND VICE VERSA | $3,433 | $1,735 | Implemented |
IA0391 # 05 Y:2006 | 05 | 2006 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $3,668 | $12,865 | Not Implemented |
IA0391 # 06 Y:2006 | 06 | 2006 | INSULATE BARE EQUIPMENT | $5,577 | $349 | Not Implemented |
IA0391 # 07 Y:2006 | 07 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $804 | $600 | Implemented |
UD0741 # 01 Y:2006 | 01 | 2006 | RE-SIZE CHARGING OPENINGS OR ADD A MOVABLE DOOR ON EQUIPMENT | $65,250 | $10,000 | Not Implemented |
UD0741 # 02 Y:2006 | 02 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,883 | $133,640 | Not Implemented |
UD0741 # 03 Y:2006 | 03 | 2006 | INSTALL TIMERS AND/OR THERMOSTATS | $18,067 | $110 | Implemented |
UD0741 # 04 Y:2006 | 04 | 2006 | KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE | $16,240 | $0 | Implemented |
UD0741 # 05 Y:2006 | 05 | 2006 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $9,135 | $2,800 | Implemented |
UD0741 # 06 Y:2006 | 06 | 2006 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,387 | $3,150 | Not Implemented |
UD0741 # 07 Y:2006 | 07 | 2006 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,802 | $840 | Implemented |
UD0741 # 08 Y:2006 | 08 | 2006 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,097 | $0 | Implemented |