Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
28
matching recommendationsSIC | 3524 | Lawn And Garden Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
GT0764 # 08 Y:2003 | 08 | 2003 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $2,368 | $36,246 | Implemented |
GT0764 # 07 Y:2003 | 07 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,150 | $5,635 | Implemented |
GT0764 # 06 Y:2003 | 06 | 2003 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $17,500 | $38,000 | Not Implemented |
GT0764 # 05 Y:2003 | 05 | 2003 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,750 | $710 | Implemented |
GT0764 # 04 Y:2003 | 04 | 2003 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $620 | $1,555 | Implemented |
GT0764 # 03 Y:2003 | 03 | 2003 | COVER OPEN TANKS | $7,550 | $2,505 | Not Implemented |
GT0764 # 02 Y:2003 | 02 | 2003 | USE SYNTHETIC LUBRICANT | $1,055 | $0 | Not Implemented |
GT0764 # 01 Y:2003 | 01 | 2003 | COVER OPEN TANKS | $17,200 | $0 | Implemented |
GT0694 # 06 Y:2000 | 06 | 2000 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $4,224 | $8,700 | Implemented |
GT0694 # 11 Y:2000 | 11 | 2000 | USE FILTRATION, CENTRIFUGING TO REMOVE CONTAMINANTS | $123,175 | $50,000 | Not Implemented |
GT0694 # 10 Y:2000 | 10 | 2000 | USE LESS WASTEFUL PACKAGING | $5,073 | $3,500 | Not Implemented |
GT0694 # 09 Y:2000 | 09 | 2000 | UTILIZE AN EVAPORATIVE AIR PRE-COOLER OR OTHER HEAT EXCHANGER IN AC SYSTEM | $2,967 | $9,200 | Not Implemented |
GT0694 # 08 Y:2000 | 08 | 2000 | COVER OPEN TANKS | $6,100 | $5,390 | Not Implemented |
GT0694 # 07 Y:2000 | 07 | 2000 | DEVELOP STANDARD OPERATING PROCEDURES | $88,200 | $34,000 | Implemented |
GT0694 # 05 Y:2000 | 05 | 2000 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $20,316 | $3,940 | Implemented |
GT0694 # 04 Y:2000 | 04 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $2,002 | $11,083 | Implemented |
GT0694 # 03 Y:2000 | 03 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,412 | $16,800 | Implemented |
GT0694 # 02 Y:2000 | 02 | 2000 | ESTABLISH BURNER MAINTENANCE SCHEDULE FOR BOILERS | $870 | $0 | Implemented |
GT0694 # 01 Y:2000 | 01 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,919 | $1,150 | Implemented |
GT0693 # 01 Y:2000 | 01 | 2000 | MODIFY STARTUP/SHUTDOWN TIMES | $96,627 | $0 | Not Implemented |
GT0693 # 09 Y:2000 | 09 | 2000 | RE-ARRANGE EQUIPMENT LAYOUT TO REDUCE LABOR COSTS | $60,000 | $120,000 | Not Implemented |
GT0693 # 08 Y:2000 | 08 | 2000 | RECOVER AND REUSE WASTE MATERIAL | $14,770 | $1,250 | Implemented |
GT0693 # 07 Y:2000 | 07 | 2000 | CHANGE RATE SCHEDULES OR OTHER CHANGES IN UTILITY SERVICE | $97,512 | $0 | Not Implemented |
GT0693 # 06 Y:2000 | 06 | 2000 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $4,972 | $1,050 | Implemented |
GT0693 # 05 Y:2000 | 05 | 2000 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $26,280 | $64,000 | Not Implemented |