IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,289

matching recommendations
Reset
SIC 353 Construction And Related Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
TN0480 # 04 Y:1993 04 1993 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $346 $1,020 Implemented
TN0480 # 05 Y:1993 05 1993 USE SYNTHETIC LUBRICANT $225 $0 Implemented
AM0170 # 02 Y:1993 02 1993 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $25,000 $0 Implemented
AM0170 # 03 Y:1993 03 1993 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $10,100 $0 Implemented
AM0170 # 07 Y:1993 07 1993 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,360 $0 Implemented
AM0170 # 08 Y:1993 08 1993 USE PHOTOCELL CONTROLS $1,155 $570 Implemented
AM0168 # 05 Y:1993 05 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,470 $420 Implemented
AM0168 # 06 Y:1993 06 1993 INSULATE BARE EQUIPMENT $990 $2,140 Implemented
AM0168 # 08 Y:1993 08 1993 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $530 $153 Implemented
AM0169 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $319 $0 Implemented
AM0169 # 03 Y:1993 03 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $810 $2,000 Implemented
WI0161 # 04 Y:1992 04 1992 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $914 $1,920 Implemented
WI0161 # 05 Y:1992 05 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $603 $128 Implemented
IA0028 # 01 Y:1992 01 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $971 $437 Implemented
IA0028 # 02 Y:1992 02 1992 INSTALL SET-BACK TIMERS $1,954 $1,701 Implemented
IA0028 # 03 Y:1992 03 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,105 $50 Implemented
IA0028 # 06 Y:1992 06 1992 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $66 $20 Implemented
TN0470 # 01 Y:1992 01 1992 USE RADIANT HEATER FOR SPOT HEATING $11,281 $5,350 Implemented
TN0470 # 02 Y:1992 02 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $8,107 $2,500 Implemented
TN0470 # 03 Y:1992 03 1992 IMPROVE LUBRICATION PRACTICES $2,404 $0 Implemented
TN0470 # 04 Y:1992 04 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $279 $99 Implemented
OK0377 # 01 Y:1992 01 1992 USE WASTE HEAT FROM FLUE GASES TO HEAT SPACE CONDITIONING AIR $17,190 $35,000 Implemented
OK0377 # 02 Y:1992 02 1992 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $8,318 $0 Implemented
OK0377 # 03 Y:1992 03 1992 KEEP LAMPS AND REFLECTORS CLEAN $2,549 $11,123 Implemented
OK0377 # 04 Y:1992 04 1992 KEEP LAMPS AND REFLECTORS CLEAN $327 $1,881 Implemented