Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
104
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WV0533 # 12 Y:2016 | 12 | 2016 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $2,004 | $2,230 | Implemented |
WV0533 # 13 Y:2016 | 13 | 2016 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $770 | $2,150 | Implemented |
WV0533 # 14 Y:2016 | 14 | 2016 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $558 | $0 | Implemented |
WV0533 # 15 Y:2016 | 15 | 2016 | INSULATE BARE EQUIPMENT | $218 | $470 | Implemented |
LE0351 # 01 Y:2013 | 01 | 2013 | INSTALL OCCUPANCY SENSORS | $5,155 | $7,480 | Implemented |
LE0351 # 02 Y:2013 | 02 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,415 | $4,700 | Not Implemented |
LE0351 # 03 Y:2013 | 03 | 2013 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,220 | $6,540 | Implemented |
LE0351 # 04 Y:2013 | 04 | 2013 | UPGRADE OBSOLETE EQUIPMENT | $3,863 | $10,000 | Implemented |
LE0351 # 05 Y:2013 | 05 | 2013 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $2,503 | $240 | Not Implemented |
LE0278 # 01 Y:2008 | 01 | 2008 | UPGRADE OBSOLETE EQUIPMENT | $94,158 | $132,748 | Not Implemented |
LE0278 # 02 Y:2008 | 02 | 2008 | TURN OFF EQUIPMENT WHEN NOT IN USE | $36,970 | $760 | Implemented |
LE0278 # 03 Y:2008 | 03 | 2008 | USE RADIANT HEATER FOR SPOT HEATING | $17,728 | $16,000 | Not Implemented |
LE0278 # 04 Y:2008 | 04 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $12,408 | $9,600 | Not Implemented |
LE0278 # 05 Y:2008 | 05 | 2008 | MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE | $10,716 | $1,200 | Not Implemented |
LE0278 # 06 Y:2008 | 06 | 2008 | INSTALL PARTITIONS TO REDUCE SIZE OF CONDITIONED SPACE | $8,828 | $7,000 | Implemented |
LE0278 # 07 Y:2008 | 07 | 2008 | RECOVER WASTE HEAT FROM EQUIPMENT | $6,783 | $7,000 | Not Implemented |
LE0278 # 08 Y:2008 | 08 | 2008 | USE OPTIMUM TEMPERATURE | $7,669 | $500 | Not Implemented |
LE0278 # 09 Y:2008 | 09 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $5,894 | $304 | Not Implemented |
LE0278 # 10 Y:2008 | 10 | 2008 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,764 | $800 | Not Implemented |
LE0278 # 11 Y:2008 | 11 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,195 | $1,824 | Implemented |
LE0278 # 12 Y:2008 | 12 | 2008 | REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC | $2,387 | $3,290 | Not Implemented |
LE0278 # 13 Y:2008 | 13 | 2008 | INSTALL TIMERS AND/OR THERMOSTATS | $1,785 | $450 | Implemented |
LE0278 # 14 Y:2008 | 14 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $52,373 | $142,010 | Implemented |
WV0379 # 01 Y:2008 | 01 | 2008 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $72,979 | $113,775 | Implemented |
WV0379 # 02 Y:2008 | 02 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $43,378 | $60,703 | Implemented |