Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
2,768
matching recommendationsSIC | 353 | Construction And Related Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0493 # 06 Y:2005 | 06 | 2005 | INSTALL SKYLIGHTS | $1,700 | $0 | Implemented |
AM0493 # 07 Y:2005 | 07 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,650 | $0 | Implemented |
AM0493 # 08 Y:2005 | 08 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $744 | $500 | Implemented |
AM0493 # 09 Y:2005 | 09 | 2005 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $760 | $0 | Not Implemented |
AM0493 # 10 Y:2005 | 10 | 2005 | USE SYNTHETIC LUBRICANT | $440 | $0 | Implemented |
AM0493 # 11 Y:2005 | 11 | 2005 | USE PHOTOCELL CONTROLS | $210 | $0 | Implemented |
LL0224 # 01 Y:2005 | 01 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $4,838 | $0 | Not Implemented |
LL0224 # 02 Y:2005 | 02 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $3,157 | $0 | Not Implemented |
LL0224 # 03 Y:2005 | 03 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,031 | $0 | Not Implemented |
LL0224 # 04 Y:2005 | 04 | 2005 | USE PHOTOCELL CONTROLS | $1,862 | $0 | Not Implemented |
LL0224 # 05 Y:2005 | 05 | 2005 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,687 | $0 | Not Implemented |
LL0224 # 06 Y:2005 | 06 | 2005 | INSTALL OCCUPANCY SENSORS | $1,284 | $0 | Not Implemented |
LL0224 # 07 Y:2005 | 07 | 2005 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $1,148 | $0 | Not Implemented |
LL0224 # 08 Y:2005 | 08 | 2005 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $296 | $0 | Not Implemented |
BD0283 # 01 Y:2005 | 01 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,694 | $3,003 | Implemented |
BD0283 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,780 | $602 | Not Implemented |
BD0283 # 03 Y:2005 | 03 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,828 | $2 | Implemented |
BD0283 # 04 Y:2005 | 04 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $2,160 | $361 | Not Implemented |
BD0283 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,700 | $851 | Implemented |
BD0283 # 06 Y:2005 | 06 | 2005 | USE PHOTOCELL CONTROLS | $1,499 | $5 | Not Implemented |
BD0283 # 07 Y:2005 | 07 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,269 | $400 | Implemented |
BD0283 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $709 | $500 | Implemented |
BD0283 # 09 Y:2005 | 09 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $352 | $0 | Implemented |
BD0283 # 10 Y:2005 | 10 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $542 | $176 | Implemented |
BD0283 # 11 Y:2005 | 11 | 2005 | MINIMIZE WATER USAGE | $495 | $0 | Not Implemented |