Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

53

matching recommendations
Reset
SIC 353 Construction And Related Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0361 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,285 $0 Not Implemented
GT0454 # 06 Y:1991 06 1991 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $2,240 $9,000 Implemented
GT0454 # 05 Y:1991 05 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,968 $1,500 Implemented
GT0454 # 04 Y:1991 04 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $104 $0 Implemented
GT0454 # 03 Y:1991 03 1991 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $130 $5,350 Implemented
GT0454 # 02 Y:1991 02 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $489 $11,450 Implemented
GT0454 # 01 Y:1991 01 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $61 $8,000 Implemented
OK0361 # 06 Y:1991 06 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $756 $0 Not Implemented
OK0361 # 05 Y:1991 05 1991 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $1,198 $107 Not Implemented
OK0361 # 04 Y:1991 04 1991 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $10,521 $13,526 Not Implemented
OK0361 # 03 Y:1991 03 1991 INSTALL TIMERS AND/OR THERMOSTATS $3,012 $1,050 Not Implemented
OK0361 # 01 Y:1991 01 1991 RECOVER WASTE HEAT FROM EQUIPMENT $307 $403 Not Implemented
OK0361 # 07 Y:1991 07 1991 REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT $2,356 $4,600 Not Implemented
RU0123 # 03 Y:1991 03 1991 USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE $7,866 $46,704 Implemented
RU0123 # 01 Y:1991 01 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,611 $0 Implemented
RU0123 # 04 Y:1991 04 1991 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $5,390 $5,320 Implemented
RU0123 # 02 Y:1991 02 1991 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $3,413 $272 Implemented
OK0353 # 05 Y:1991 05 1991 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $88 $120 Not Implemented
OK0353 # 02 Y:1991 02 1991 REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED $234 $0 Not Implemented
OK0353 # 03 Y:1991 03 1991 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $379 $0 Not Implemented
OK0353 # 04 Y:1991 04 1991 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $200 $0 Not Implemented
OK0353 # 01 Y:1991 01 1991 INSTALL TIMERS AND/OR THERMOSTATS $3,147 $1,050 Not Implemented
OK0355 # 04 Y:1991 04 1991 INSTALL TIMERS AND/OR THERMOSTATS $3,475 $1,745 Implemented
OK0355 # 03 Y:1991 03 1991 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $4,136 $9,186 Implemented
OK0355 # 05 Y:1991 05 1991 INSTALL TIMERS AND/OR THERMOSTATS $1,411 $1,150 Implemented