Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
829
matching recommendationsSIC | 3531 | Construction Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
KU0112 # 07 Y:1984 | 07 | 1984 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,000 | $360 | Not Implemented |
KU0112 # 08 Y:1984 | 08 | 1984 | REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED | $286 | $0 | Implemented |
KU0112 # 09 Y:1984 | 09 | 1984 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $625 | $300 | Not Implemented |
UD0067 # 01 Y:1982 | 01 | 1982 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $1,431 | $250 | Implemented |
UD0067 # 02 Y:1982 | 02 | 1982 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $12,896 | $64,600 | Implemented |
UD0067 # 03 Y:1982 | 03 | 1982 | INSTALL STORM WINDOWS AND DOORS | $6,999 | $7,642 | Implemented |
UD0067 # 04 Y:1982 | 04 | 1982 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $1,770 | $0 | Implemented |
UD0067 # 05 Y:1982 | 05 | 1982 | UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING | $1,207 | $286 | Implemented |
OK0044 # 01 Y:1982 | 01 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $47,030 | $3,200 | Not Implemented |
OK0044 # 02 Y:1982 | 02 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,390 | $500 | Not Implemented |
OK0044 # 03 Y:1982 | 03 | 1982 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $12,550 | $23,600 | Not Implemented |
OK0044 # 04 Y:1982 | 04 | 1982 | INSTALL STORM WINDOWS AND DOORS | $815 | $3,360 | Not Implemented |
OK0038 # 01 Y:1982 | 01 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $217 | $313 | Not Implemented |
OK0038 # 02 Y:1982 | 02 | 1982 | USE RADIANT HEATER FOR SPOT HEATING | $23,027 | $29,970 | Not Implemented |
OK0038 # 03 Y:1982 | 03 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $259 | $165 | Not Implemented |
OK0038 # 04 Y:1982 | 04 | 1982 | INSTALL STORM WINDOWS AND DOORS | $4,750 | $17,358 | Not Implemented |
OK0050 # 01 Y:1982 | 01 | 1982 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,801 | $180 | Not Implemented |
OK0050 # 02 Y:1982 | 02 | 1982 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $187 | $330 | Not Implemented |
OK0050 # 03 Y:1982 | 03 | 1982 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $199 | $17 | Not Implemented |
OK0050 # 04 Y:1982 | 04 | 1982 | USE ONLY AMOUNT OF AIR NECESSARY TO PREVENT EXPLOSION HAZARD | $7,642 | $80 | Not Implemented |
OK0050 # 05 Y:1982 | 05 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $275 | $790 | Not Implemented |
OK0050 # 06 Y:1982 | 06 | 1982 | REDUCE FLUID FLOW RATES | $595 | $0 | Not Implemented |
TN0121 # 01 Y:1982 | 01 | 1982 | INSTALL SET-BACK TIMERS | $1,720 | $0 | Not Implemented |
TN0121 # 02 Y:1982 | 02 | 1982 | INSTALL TIMERS AND/OR THERMOSTATS | $953 | $0 | Not Implemented |
TN0121 # 03 Y:1982 | 03 | 1982 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $485 | $700 | Not Implemented |