Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
286
matching recommendationsSIC | 3533 | Oil And Gas Field Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AM0215 # 03 Y:1994 | 03 | 1994 | INSTALL TIMERS AND/OR THERMOSTATS | $2,710 | $600 | Not Implemented |
AM0215 # 04 Y:1994 | 04 | 1994 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $2,240 | $0 | Implemented |
AM0215 # 05 Y:1994 | 05 | 1994 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,165 | $25 | Implemented |
AM0215 # 06 Y:1994 | 06 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,510 | $1,920 | Implemented |
AM0215 # 07 Y:1994 | 07 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $460 | $930 | Implemented |
AM0206 # 01 Y:1994 | 01 | 1994 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $10,300 | $12,060 | Not Implemented |
AM0206 # 02 Y:1994 | 02 | 1994 | OPTIMIZE PLANT POWER FACTOR | $5,850 | $9,085 | Not Implemented |
AM0206 # 03 Y:1994 | 03 | 1994 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $5,600 | $11,590 | Implemented |
AM0206 # 04 Y:1994 | 04 | 1994 | TURN OFF EQUIPMENT WHEN NOT IN USE | $2,840 | $670 | Implemented |
AM0206 # 05 Y:1994 | 05 | 1994 | INSTALL SKYLIGHTS | $1,920 | $9,040 | Not Implemented |
AM0206 # 06 Y:1994 | 06 | 1994 | USE RADIANT HEATER FOR SPOT HEATING | $1,710 | $990 | Not Implemented |
AM0206 # 07 Y:1994 | 07 | 1994 | PAY UTILITY BILLS ON TIME | $855 | $0 | Not Implemented |
AM0190 # 01 Y:1993 | 01 | 1993 | INSTALL SKYLIGHTS | $3,620 | $3,430 | Not Implemented |
AM0190 # 02 Y:1993 | 02 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $1,375 | $1,200 | Implemented |
AM0190 # 03 Y:1993 | 03 | 1993 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $1,180 | $540 | Implemented |
AM0190 # 04 Y:1993 | 04 | 1993 | APPLY FOR TAX-FREE STATUS FOR ENERGY PURCHASES | $575 | $1,000 | Not Implemented |
AM0190 # 05 Y:1993 | 05 | 1993 | PAY UTILITY BILLS ON TIME | $440 | $0 | Implemented |
AM0190 # 06 Y:1993 | 06 | 1993 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $225 | $0 | Not Implemented |
AM0186 # 01 Y:1993 | 01 | 1993 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $272,040 | $100,000 | Not Implemented |
AM0186 # 02 Y:1993 | 02 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $33,670 | $0 | Implemented |
AM0186 # 03 Y:1993 | 03 | 1993 | OPTIMIZE PLANT POWER FACTOR | $17,400 | $68,000 | Not Implemented |
AM0186 # 04 Y:1993 | 04 | 1993 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $17,300 | $0 | Not Implemented |
AM0186 # 05 Y:1993 | 05 | 1993 | CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE | $7,460 | $0 | Implemented |
AM0186 # 06 Y:1993 | 06 | 1993 | SIZE ELECTRIC MOTORS FOR PEAK OPERATING EFFICIENCY | $5,540 | $2,000 | Not Implemented |
AM0174 # 01 Y:1993 | 01 | 1993 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $6,460 | $0 | Not Implemented |