Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
27
matching recommendationsSIC | 3535 | Conveyors And Conveying Equipment |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
BD0388 # 05 Y:2011 | 05 | 2011 | USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS | $63,847 | $26,000 | Not Implemented |
BD0388 # 04 Y:2011 | 04 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,581 | $1,200 | Not Implemented |
BD0388 # 03 Y:2011 | 03 | 2011 | REDUCE COMBUSTION AIR FLOW TO OPTIMUM | $2,470 | $4,000 | Not Implemented |
BD0388 # 02 Y:2011 | 02 | 2011 | USE RADIANT HEATER FOR SPOT HEATING | $30,750 | $20,000 | Not Implemented |
BD0388 # 01 Y:2011 | 01 | 2011 | REPLACE HEAT TREATING OVEN WITH MORE EFFICIENT UNIT | $12,465 | $60,000 | Not Implemented |
BD0283 # 02 Y:2005 | 02 | 2005 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $4,780 | $602 | Not Implemented |
BD0283 # 13 Y:2005 | 13 | 2005 | AUTOMATE PAYROLL SYSTEM | $4,576 | $502 | Not Implemented |
BD0283 # 12 Y:2005 | 12 | 2005 | INSTALL AUTOMATIC PACKING EQUIPMENT | $31,608 | $15 | Not Implemented |
BD0283 # 11 Y:2005 | 11 | 2005 | MINIMIZE WATER USAGE | $495 | $0 | Not Implemented |
BD0283 # 09 Y:2005 | 09 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $352 | $0 | Implemented |
BD0283 # 08 Y:2005 | 08 | 2005 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $709 | $500 | Implemented |
BD0283 # 07 Y:2005 | 07 | 2005 | USE DEMAND CONTROLLER OR LOAD SHEDDER | $1,269 | $400 | Implemented |
BD0283 # 06 Y:2005 | 06 | 2005 | USE PHOTOCELL CONTROLS | $1,499 | $5 | Not Implemented |
BD0283 # 05 Y:2005 | 05 | 2005 | INSTALL OCCUPANCY SENSORS | $1,700 | $851 | Implemented |
BD0283 # 04 Y:2005 | 04 | 2005 | USE RADIANT HEATER FOR SPOT HEATING | $2,160 | $361 | Not Implemented |
BD0283 # 03 Y:2005 | 03 | 2005 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $2,828 | $2 | Implemented |
BD0283 # 01 Y:2005 | 01 | 2005 | RE-SIZE CHARGING OPENINGS OR ADD MOVABLE COVER OR DOOR | $5,694 | $3,003 | Implemented |
BD0283 # 10 Y:2005 | 10 | 2005 | REUSE / RECYCLE/ SELL PAPER PRODUCTS | $542 | $176 | Implemented |
WI0175 # 09 Y:1993 | 09 | 1993 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $222 | $444 | Not Implemented |
WI0175 # 08 Y:1993 | 08 | 1993 | INSTALL OCCUPANCY SENSORS | $331 | $200 | Not Implemented |
WI0175 # 07 Y:1993 | 07 | 1993 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $740 | $1,584 | Implemented |
WI0175 # 06 Y:1993 | 06 | 1993 | TURN OFF EQUIPMENT WHEN NOT IN USE | $972 | $800 | Not Implemented |
WI0175 # 05 Y:1993 | 05 | 1993 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $1,329 | $0 | Not Implemented |
WI0175 # 04 Y:1993 | 04 | 1993 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $1,672 | $4,650 | Implemented |
WI0175 # 03 Y:1993 | 03 | 1993 | REPLACE HYDRAULIC / PNEUMATIC EQUIPMENT WITH ELECTRIC EQUIPMENT | $2,118 | $675 | Not Implemented |