Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

361

matching recommendations
Reset
SIC 354 Metalworking Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
WV0095 # 01 Y:1996 01 1996 USE POWER DURING OFF-PEAK PERIODS $24,235 $0 Implemented
WV0095 # 02 Y:1996 02 1996 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $4,565 $550 Implemented
WV0095 # 03 Y:1996 03 1996 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $466 $700 Implemented
WV0095 # 04 Y:1996 04 1996 DIRECT WARMEST AIR TO COMBUSTION INTAKE $534 $2,105 Not Implemented
WV0095 # 05 Y:1996 05 1996 INSTALL / REPAIR INSULATION ON STEAM LINES $1,811 $2,743 Implemented
WV0095 # 06 Y:1996 06 1996 TURN OFF EQUIPMENT WHEN NOT IN USE $580 $0 Implemented
WV0095 # 07 Y:1996 07 1996 MINIMIZE USE OF OUTSIDE MAKE-UP AIR FOR VENTILATION EXCEPT WHEN USED FOR ECONOMIZER CYCLE $8,019 $2,940 Not Implemented
WV0095 # 08 Y:1996 08 1996 IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS $2,432 $2,800 Not Implemented
WV0095 # 09 Y:1996 09 1996 LEASE / PURCHASE BALER; SELL CARDBOARD TO RECYCLER $11,260 $9,000 Implemented
UD0470 # 01 Y:1995 01 1995 SUBSTITUTE COMPRESSED AIR COOLING WITH WATER OR AIR COOLING $12,036 $15,000 Implemented
UD0470 # 02 Y:1995 02 1995 RECOVER WASTE HEAT FROM EQUIPMENT $619 $2,500 Not Implemented
UD0470 # 03 Y:1995 03 1995 DISCONNECT BALLASTS $934 $100 Not Implemented
WV0061 # 01 Y:1995 01 1995 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,417 $1,162 Implemented
WV0061 # 02 Y:1995 02 1995 MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED $5,239 $3,730 Implemented
WV0061 # 03 Y:1995 03 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $1,045 $0 Implemented
WV0061 # 04 Y:1995 04 1995 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,441 $7,970 Implemented
WV0061 # 05 Y:1995 05 1995 INSULATE BARE EQUIPMENT $3,388 $1,804 Not Implemented
WV0061 # 06 Y:1995 06 1995 INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT $6,013 $6,000 Not Implemented
WV0061 # 07 Y:1995 07 1995 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $229 $90 Not Implemented
WV0061 # 08 Y:1995 08 1995 RECOVER WASTE HEAT FROM EQUIPMENT $384 $670 Not Implemented
WV0061 # 09 Y:1995 09 1995 USE SYNTHETIC LUBRICANT $239 $0 Not Implemented
UD0448 # 01 Y:1994 01 1994 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $7,413 $20,000 Implemented
UD0448 # 02 Y:1994 02 1994 REDUCE VENTILATION AIR $1,250 $2,500 Not Implemented
UD0448 # 03 Y:1994 03 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,068 $10,425 Implemented
UD0448 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,798 $6,200 Implemented