Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
119
matching recommendationsSIC | 354 | Metalworking Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
SD0251 # 07 Y:2000 | 07 | 2000 | USE FLUE GASES TO HEAT PROCESS OR SERVICE WATER | $1,315 | $1,000 | Not Implemented |
SD0251 # 08 Y:2000 | 08 | 2000 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $2,240 | $7,900 | Implemented |
SD0251 # 09 Y:2000 | 09 | 2000 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $75,350 | $10,050 | Not Implemented |
SD0161 # 01 Y:1997 | 01 | 1997 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $24,903 | $21,360 | Implemented |
SD0161 # 02 Y:1997 | 02 | 1997 | REPLACE BOILER | $38,307 | $8,000 | Not Implemented |
SD0161 # 03 Y:1997 | 03 | 1997 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $14,372 | $0 | Implemented |
SD0161 # 04 Y:1997 | 04 | 1997 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $4,046 | $4,000 | Implemented |
SD0161 # 05 Y:1997 | 05 | 1997 | USE OPTIMUM THICKNESS INSULATION | $3,460 | $108 | Implemented |
SD0161 # 06 Y:1997 | 06 | 1997 | UTILIZE A LESS EXPENSIVE COOLING METHOD | $2,460 | $900 | Not Implemented |
SD0161 # 07 Y:1997 | 07 | 1997 | REPLACE EXISTING EQUIPMENT WITH MORE SUITABLE SUBSTITUTES | $1,573 | $1,800 | Not Implemented |
SD0161 # 08 Y:1997 | 08 | 1997 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $965 | $2,700 | Implemented |
SD0161 # 09 Y:1997 | 09 | 1997 | INSTALL SPECTRAL REFLECTORS / DELAMP | $8,614 | $10,360 | Implemented |
SD0161 # 10 Y:1997 | 10 | 1997 | INSTALL OCCUPANCY SENSORS | $1,963 | $820 | Implemented |
SD0161 # 11 Y:1997 | 11 | 1997 | USE LESS TOXIC AND VOLATILE SOLVENT SUBSTITUTES | $496 | $0 | Implemented |
SD0161 # 12 Y:1997 | 12 | 1997 | INSTALL EQUIPMENT (eg COMPACTOR) TO REDUCE DISPOSAL COSTS | $14,696 | $9,000 | Implemented |
SD0161 # 13 Y:1997 | 13 | 1997 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $33,136 | $8,000 | Not Implemented |
SD0161 # 14 Y:1997 | 14 | 1997 | CLEAR AND RENT EXISTING SPACE | $23,046 | $152 | Implemented |
SD0161 # 15 Y:1997 | 15 | 1997 | CONDENSE OPERATION INTO ONE BUILDING | $48,384 | $0 | Implemented |
NV0070 # 01 Y:1996 | 01 | 1996 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $6,386 | $20 | Implemented |
NV0070 # 02 Y:1996 | 02 | 1996 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $743 | $200 | Implemented |
NV0070 # 03 Y:1996 | 03 | 1996 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $413 | $0 | Implemented |
NV0070 # 04 Y:1996 | 04 | 1996 | INSTALL OCCUPANCY SENSORS | $968 | $282 | Implemented |
NV0070 # 05 Y:1996 | 05 | 1996 | REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT | $1,846 | $920 | Implemented |
NV0070 # 06 Y:1996 | 06 | 1996 | USE OPTIMUM SIZE AND CAPACITY EQUIPMENT | $3,238 | $180 | Implemented |
NV0070 # 07 Y:1996 | 07 | 1996 | IMPLEMENT A MACHINE AND COOLANT SUMP CLEANING PROGRAM TO MINIMIZE COOLANT CONTAMINATION | $5,400 | $10,000 | Not Implemented |