Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,910

matching recommendations
Reset
SIC 354 Metalworking Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
UD0267 # 04 Y:1988 04 1988 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $1,285 $552 Implemented
AM0037 # 01 Y:1988 01 1988 USE DEMAND CONTROLLER OR LOAD SHEDDER $7,390 $12,000 Implemented
AM0037 # 02 Y:1988 02 1988 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,550 $1,000 Implemented
AM0037 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,881 $373 Implemented
AM0037 # 04 Y:1988 04 1988 INSTALL SET-BACK TIMERS $1,280 $0 Implemented
AM0037 # 05 Y:1988 05 1988 INSULATE BARE EQUIPMENT $860 $740 Implemented
AM0037 # 06 Y:1988 06 1988 IMPROVE LUBRICATION PRACTICES $370 $0 Implemented
AM0037 # 07 Y:1988 07 1988 MAINTAIN AIR FILTERS BY CLEANING OR REPLACEMENT $68 $150 Not Implemented
AM0037 # 08 Y:1988 08 1988 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME $120 $100 Implemented
WI0023 # 01 Y:1988 01 1988 IMPROVE LUBRICATION PRACTICES $2,680 $0 Not Implemented
WI0023 # 02 Y:1988 02 1988 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $327 $500 Implemented
WI0023 # 03 Y:1988 03 1988 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $259 $163 Implemented
WI0023 # 04 Y:1988 04 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $716 $500 Implemented
WI0023 # 05 Y:1988 05 1988 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $104 $0 Implemented
UD0235 # 01 Y:1987 01 1987 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $3,496 $500 Implemented
UD0235 # 02 Y:1987 02 1987 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $1,497 $0 Implemented
UD0235 # 03 Y:1987 03 1987 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,823 $2,986 Not Implemented
LT0052 # 01 Y:1986 01 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $5,660 $1,476 Implemented
LT0052 # 02 Y:1986 02 1986 REPAIR FAULTY INSULATION IN FURNACES, BOILERS, ETC $3,370 $1,220 Not Implemented
LT0052 # 03 Y:1986 03 1986 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,795 $4,990 Implemented
LT0052 # 04 Y:1986 04 1986 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $1,659 $1,632 Implemented
LT0052 # 05 Y:1986 05 1986 UTILIZE DAYLIGHT WHENEVER POSSIBLE IN LIEU OF ARTIFICIAL LIGHT $735 $770 Not Implemented
LT0052 # 06 Y:1986 06 1986 INSTALL SET-BACK TIMERS $1,865 $0 Implemented
LT0052 # 07 Y:1986 07 1986 PLANT TREES OR SHRUBS NEAR WINDOWS TO SHIELD FROM SUNLIGHT $556 $1,470 Not Implemented
KU0202 # 01 Y:1986 01 1986 INSTALL TIMERS AND/OR THERMOSTATS $17,707 $200 Implemented