IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

611

matching recommendations
Reset
SIC 3544 Special Dies, Tools, Jigs & Fixtures
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0645 # 06 Y:2002 06 2002 TRAIN OPERATORS FOR MAXIMUM OPERATING EFFICIENCY $61,280 $44,000 Implemented
WV0238 # 01 Y:2002 01 2002 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,740 $100 Implemented
WV0238 # 02 Y:2002 02 2002 CHILL WATER TO THE HIGHEST TEMPERATURE POSSIBLE $424 $60 Implemented
WV0238 # 03 Y:2002 03 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,462 $188 Not Implemented
WV0238 # 04 Y:2002 04 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,250 $315 Implemented
WV0238 # 05 Y:2002 05 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,894 $2,910 Implemented
WV0238 # 06 Y:2002 06 2002 USE / PURCHASE OPTIMUM SIZED COMPRESSOR $5,806 $0 Implemented
WV0238 # 07 Y:2002 07 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $649 $450 Implemented
WV0238 # 08 Y:2002 08 2002 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $4,813 $0 Implemented
WV0238 # 09 Y:2002 09 2002 USE OUTSIDE COLD WATER SOURCE AS A SUPPLY OF COOLING WATER $6,165 $0 Not Implemented
WV0238 # 10 Y:2002 10 2002 USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY $1,562 $150 Implemented
WV0238 # 11 Y:2002 11 2002 SELL / OFFER BY-PRODUCT AS ANIMAL FEED $2,080 $100 Implemented
WV0238 # 12 Y:2002 12 2002 CONTRACT A WOOD PALLET RECYCLING COMPANY $1,560 $100 Implemented
WV0238 # 13 Y:2002 13 2002 USE FIXTURES TO REDUCE MACHINE CHANGEOUT TIMES $11,520 $1,620 Not Implemented
WI0420 # 01 Y:2002 01 2002 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $41,849 $203,000 Not Implemented
WI0420 # 02 Y:2002 02 2002 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $6,868 $933 Implemented
WI0420 # 03 Y:2002 03 2002 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,832 $1,601 Not Implemented
WI0420 # 04 Y:2002 04 2002 REPLACE CLOTH RAGS WITH PAPER TOWELS $1,012 $0 Not Implemented
WI0420 # 05 Y:2002 05 2002 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $993 $2,094 Not Implemented
WI0420 # 06 Y:2002 06 2002 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $576 $640 Implemented
WI0420 # 07 Y:2002 07 2002 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $315 $543 Implemented
WI0420 # 08 Y:2002 08 2002 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $315 $0 Not Implemented
LM0008 # 01 Y:2001 01 2001 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $2,518 $500 Implemented
LM0008 # 02 Y:2001 02 2001 USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM $44,725 $15,270 Not Implemented
LM0008 # 03 Y:2001 03 2001 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $787 $0 Implemented