Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

410

matching recommendations
Reset
SIC 3545 Machine Tool Accessories
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
OK0443 # 03 Y:1994 03 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $800 $0 Implemented
OK0443 # 04 Y:1994 04 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $8,381 $12,960 Not Implemented
MA0289 # 01 Y:1993 01 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $8,282 $20,878 Implemented
MA0289 # 02 Y:1993 02 1993 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,675 $4,811 Not Implemented
MA0289 # 03 Y:1993 03 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $486 $67 Implemented
MA0289 # 04 Y:1993 04 1993 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,948 $180 Implemented
ME0103 # 01 Y:1993 01 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $1,228 $180 Not Implemented
ME0103 # 02 Y:1993 02 1993 RECOVER WASTE HEAT FROM EQUIPMENT $1,470 $1,300 Not Implemented
ME0103 # 03 Y:1993 03 1993 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT $69,216 $175,000 Not Implemented
ME0103 # 04 Y:1993 04 1993 SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS $8,100 $20,000 Not Implemented
ME0103 # 05 Y:1993 05 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $3,120 $700 Implemented
ME0103 # 06 Y:1993 06 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $14,129 $13,680 Not Implemented
ME0103 # 07 Y:1993 07 1993 PAY UTILITY BILLS ON TIME $2,223 $0 Implemented
ME0102 # 01 Y:1993 01 1993 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $486 $90 Not Implemented
ME0102 # 02 Y:1993 02 1993 RECOVER WASTE HEAT FROM EQUIPMENT $3,485 $8,690 Not Implemented
ME0102 # 03 Y:1993 03 1993 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $3,038 $7,200 Implemented
ME0102 # 04 Y:1993 04 1993 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $1,674 $1,400 Implemented
ME0102 # 05 Y:1993 05 1993 OPTIMIZE PLANT POWER FACTOR $1,363 $0 Not Implemented
MA0259 # 01 Y:1992 01 1992 REDUCE TEMPERATURE OF PROCESS EQUIPMENT WHEN ON STANDBY $8,134 $0 Not Implemented
MA0259 # 02 Y:1992 02 1992 BURN A LESS EXPENSIVE GRADE OF FUEL $3,084 $0 Not Implemented
MA0259 # 03 Y:1992 03 1992 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $487 $0 Not Implemented
MA0259 # 04 Y:1992 04 1992 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $562 $509 Not Implemented
MA0259 # 05 Y:1992 05 1992 DIRECT WARMEST AIR TO COMBUSTION INTAKE $686 $2,108 Not Implemented
MA0259 # 06 Y:1992 06 1992 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $584 $0 Not Implemented
MA0259 # 07 Y:1992 07 1992 INSTALL / REPAIR INSULATION ON CONDENSATE LINES $396 $168 Not Implemented