Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
17
matching recommendationsSIC | 3549 | Metalworking Machinery, Nec |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0632 # 02 Y:2001 | 02 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $33,500 | $6,000 | Not Implemented |
UD0632 # 10 Y:2001 | 10 | 2001 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $207 | $300 | Not Implemented |
UD0632 # 09 Y:2001 | 09 | 2001 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $307 | $12 | Not Implemented |
UD0632 # 08 Y:2001 | 08 | 2001 | INSULATE BARE EQUIPMENT | $315 | $435 | Not Implemented |
UD0632 # 07 Y:2001 | 07 | 2001 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $1,355 | $0 | Not Implemented |
UD0632 # 06 Y:2001 | 06 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,400 | $1,846 | Not Implemented |
UD0632 # 05 Y:2001 | 05 | 2001 | USE DRYING OVEN (BATCH TYPE) ON ALTERNATE DAYS OR OTHER OPTIMUM SCHEDULE TO RUN EQUIPMENT WITH FULL LOADS | $5,264 | $0 | Implemented |
UD0632 # 04 Y:2001 | 04 | 2001 | USE / PURCHASE OPTIMUM SIZED COMPRESSOR | $9,915 | $0 | Implemented |
UD0632 # 03 Y:2001 | 03 | 2001 | OPTIMIZE PRODUCTION LOT SIZES AND INVENTORIES | $15,075 | $0 | Not Implemented |
UD0632 # 01 Y:2001 | 01 | 2001 | OPTIMIZE PLANT POWER FACTOR | $94,812 | $8,000 | Implemented |
UD0622 # 01 Y:2001 | 01 | 2001 | ADD EQUIPMENT/ OPERATORS TO REDUCE PRODUCTION BOTTLENECK | $12,500 | $2,500 | Implemented |
UD0622 # 07 Y:2001 | 07 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $67 | $170 | Implemented |
UD0622 # 06 Y:2001 | 06 | 2001 | INSTALL SKYLIGHTS | $1,341 | $4,455 | Not Implemented |
UD0622 # 05 Y:2001 | 05 | 2001 | REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER | $2,978 | $9,800 | Not Implemented |
UD0622 # 04 Y:2001 | 04 | 2001 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,574 | $6,830 | Implemented |
UD0622 # 03 Y:2001 | 03 | 2001 | UTILIZE A CENTRAL COOLANT SYSTEM FOR CLEANING AND REUSE OF METAL WORKING FLUID | $5,610 | $3,200 | Not Implemented |
UD0622 # 02 Y:2001 | 02 | 2001 | REPROCESS SPENT OILS ON SITE FOR RE-USE | $9,526 | $3,323 | Not Implemented |