Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
1,577
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
UD0854 # 02 Y:2012 | 02 | 2012 | SCHEDULE BAKING TIMES OF SMALL AND LARGE COMPONENTS | $5,889 | $0 | Not Implemented |
UD0854 # 03 Y:2012 | 03 | 2012 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $291 | $0 | Not Implemented |
UD0854 # 04 Y:2012 | 04 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $1,511 | $1,500 | Not Implemented |
UD0854 # 05 Y:2012 | 05 | 2012 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $1,351 | $0 | Not Implemented |
UD0854 # 06 Y:2012 | 06 | 2012 | REDUCE VENTILATION AIR | $8,795 | $0 | Not Implemented |
UD0854 # 07 Y:2012 | 07 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,906 | $0 | Not Implemented |
UD0854 # 08 Y:2012 | 08 | 2012 | INSULATE GLAZING, WALLS, CEILINGS, AND ROOFS | $513 | $857 | Not Implemented |
DL0085 # 01 Y:2012 | 01 | 2012 | SEPARATE CONTROLS OF AIR HANDLERS FROM AC/ HEATING SYSTEMS | $37,175 | $100 | Not Implemented |
DL0085 # 02 Y:2012 | 02 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,948 | $100 | Implemented |
DL0085 # 03 Y:2012 | 03 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,212 | $6,080 | Implemented |
DL0085 # 04 Y:2012 | 04 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $25,500 | $21,080 | Implemented |
DL0085 # 05 Y:2012 | 05 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $32,910 | $51,500 | Implemented |
DL0085 # 06 Y:2012 | 06 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,995 | $4,850 | Implemented |
DL0085 # 07 Y:2012 | 07 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,020 | $2,800 | Implemented |
DL0085 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $2,640 | $620 | Implemented |
DL0085 # 09 Y:2012 | 09 | 2012 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $23,794 | $80,000 | Not Implemented |
DL0085 # 10 Y:2012 | 10 | 2012 | REVISE SMOKE CLEANUP FROM OPERATIONS | $3,290 | $11,200 | Implemented |
DL0085 # 11 Y:2012 | 11 | 2012 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $5,894 | $11,040 | Not Implemented |
DL0085 # 12 Y:2012 | 12 | 2012 | TURN OFF EQUIPMENT WHEN NOT IN USE | $1,010 | $500 | Not Implemented |
UD0833 # 01 Y:2011 | 01 | 2011 | INSTALL OCCUPANCY SENSORS | $2,272 | $300 | Implemented |
UD0833 # 02 Y:2011 | 02 | 2011 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $4,467 | $25 | Implemented |
UD0833 # 03 Y:2011 | 03 | 2011 | UPGRADE CONTROLS ON COMPRESSORS | $24,064 | $1,075 | Not Implemented |
UD0833 # 04 Y:2011 | 04 | 2011 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $5,026 | $500 | Not Implemented |
UD0833 # 05 Y:2011 | 05 | 2011 | UPGRADE OBSOLETE EQUIPMENT | $3,710 | $12,661 | Not Implemented |
UD0833 # 06 Y:2011 | 06 | 2011 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $3,343 | $500 | Implemented |