IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

1,555

matching recommendations
Reset
SIC 355 Special Industry Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
CO0040 # 09 Y:1985 09 1985 INSTALL / REPAIR INSULATION ON STEAM LINES $555 $700 Implemented
CO0040 # 10 Y:1985 10 1985 USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT $3,094 $5,000 Not Implemented
CO0040 # 11 Y:1985 11 1985 INCREASE AMOUNT OF CONDENSATE RETURNED $3,959 $9,000 Implemented
CO0040 # 12 Y:1985 12 1985 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS $7,066 $1,000 Implemented
TS0009 # 01 Y:1985 01 1985 UTILIZE OUTSIDE AIR INSTEAD OF CONDITIONED AIR FOR DRYING $14,940 $8,000 Not Implemented
TS0009 # 02 Y:1985 02 1985 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $111 $10 Not Implemented
TS0009 # 03 Y:1985 03 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $3,498 $0 Not Implemented
TS0009 # 04 Y:1985 04 1985 KEEP DOORS AND WINDOWS SHUT WHEN NOT ON USE $2,460 $1,200 Not Implemented
TS0009 # 05 Y:1985 05 1985 ELIMINATE OR REDUCE COMPRESSED AIR USAGE $400 $0 Not Implemented
TS0009 # 06 Y:1985 06 1985 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS $581 $600 Not Implemented
UD0148 # 01 Y:1985 01 1985 RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS $4,500 $300 Implemented
UD0148 # 02 Y:1985 02 1985 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $4,111 $2,395 Implemented
UD0148 # 03 Y:1985 03 1985 INSULATE BARE EQUIPMENT $994 $1,560 Not Implemented
ST0009 # 01 Y:1984 01 1984 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $2,275 $212 Not Implemented
ST0009 # 02 Y:1984 02 1984 ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO $201 $537 Implemented
ST0009 # 03 Y:1984 03 1984 SHUT OFF PILOTS IN STANDBY EQUIPMENT $50 $0 Implemented
ST0009 # 04 Y:1984 04 1984 REDUCE HOT WATER TEMPERATURE TO THE MINIMUM REQUIRED $136 $0 Implemented
ST0009 # 05 Y:1984 05 1984 INSTALL / REPAIR INSULATION ON STEAM LINES $40 $50 Implemented
ST0009 # 06 Y:1984 06 1984 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $32 $28 Not Implemented
ST0009 # 07 Y:1984 07 1984 INSTALL AUTOMATIC STACK DAMPER $251 $60 Not Implemented
ST0009 # 08 Y:1984 08 1984 LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA $2,149 $0 Implemented
ST0009 # 09 Y:1984 09 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $679 $130 Not Implemented
ST0009 # 10 Y:1984 10 1984 INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS $370 $750 Not Implemented
LT0010 # 01 Y:1984 01 1984 INSULATE BARE EQUIPMENT $157 $200 Implemented
LT0010 # 02 Y:1984 02 1984 COVER OPEN TANKS $174 $48 Implemented