Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
21
matching recommendationsSIC | 355 | Special Industry Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
AS0434 # 07 Y:2017 | 07 | 2017 | TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME | $307 | $60 | Implemented |
AS0434 # 06 Y:2017 | 06 | 2017 | MINIMIZE OPERATION OF EQUIPMENT MAINTAINED IN STANDBY CONDITION | $461 | $450 | Not Implemented |
AS0434 # 05 Y:2017 | 05 | 2017 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,564 | $60 | Not Implemented |
AS0434 # 04 Y:2017 | 04 | 2017 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,250 | $2,513 | Not Implemented |
AS0434 # 03 Y:2017 | 03 | 2017 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $11,405 | $1,200 | Not Implemented |
AS0434 # 02 Y:2017 | 02 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $43,502 | $4,394 | Not Implemented |
AS0434 # 01 Y:2017 | 01 | 2017 | UPGRADE CONTROLS ON COMPRESSORS | $68,034 | $6,582 | Not Implemented |
AS0431 # 02 Y:2006 | 02 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $1,413 | $1,500 | n/a |
AS0431 # 05 Y:2006 | 05 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $370 | $1,000 | n/a |
AS0431 # 04 Y:2006 | 04 | 2006 | ANALYZE FLUE GAS FOR PROPER AIR/FUEL RATIO | $401 | $1,500 | n/a |
AS0431 # 03 Y:2006 | 03 | 2006 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $529 | $1,500 | n/a |
AS0431 # 01 Y:2006 | 01 | 2006 | USE SOLAR HEAT TO HEAT WATER | $1,728 | $8,800 | n/a |
AS0238 # 01 Y:1998 | 01 | 1998 | INSTALL TIMERS AND/OR THERMOSTATS | $901 | $1,875 | Not Implemented |
AS0238 # 02 Y:1998 | 02 | 1998 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,256 | $16,930 | Not Implemented |
AS0238 # 03 Y:1998 | 03 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $1,014 | $60 | Not Implemented |
AS0238 # 04 Y:1998 | 04 | 1998 | APPLY FOR INVESTMENT INCENTIVES | $1,436 | $60 | Not Implemented |
AS0237 # 04 Y:1998 | 04 | 1998 | RECOVER AND REUSE COOLING WATER | $1,500 | $3,000 | Not Implemented |
AS0237 # 05 Y:1998 | 05 | 1998 | APPLY FOR INVESTMENT INCENTIVES | $2,851 | $60 | Not Implemented |
AS0237 # 03 Y:1998 | 03 | 1998 | USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL | $6,136 | $60 | Not Implemented |
AS0237 # 02 Y:1998 | 02 | 1998 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $2,106 | $60 | Not Implemented |
AS0237 # 01 Y:1998 | 01 | 1998 | INSTALL OCCUPANCY SENSORS | $791 | $2,613 | Not Implemented |