Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
51
matching recommendationsSIC | 3554 | Paper Industries Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
DL0085 # 02 Y:2012 | 02 | 2012 | REDUCE SPACE CONDITIONING DURING NON-WORKING HOURS | $7,948 | $100 | Implemented |
DL0085 # 03 Y:2012 | 03 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,212 | $6,080 | Implemented |
DL0085 # 04 Y:2012 | 04 | 2012 | INSTALL OUTSIDE AIR DAMPER / ECONOMIZER ON HVAC UNIT | $25,500 | $21,080 | Implemented |
DL0085 # 05 Y:2012 | 05 | 2012 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $32,910 | $51,500 | Implemented |
DL0085 # 06 Y:2012 | 06 | 2012 | RECOVER WASTE HEAT FROM EQUIPMENT | $7,995 | $4,850 | Implemented |
DL0085 # 07 Y:2012 | 07 | 2012 | USE ADJUSTABLE FREQUENCY DRIVE OR MULTIPLE SPEED MOTORS ON EXISTING SYSTEM | $4,020 | $2,800 | Implemented |
DL0085 # 08 Y:2012 | 08 | 2012 | INSTALL OCCUPANCY SENSORS | $2,640 | $620 | Implemented |
DL0085 # 10 Y:2012 | 10 | 2012 | REVISE SMOKE CLEANUP FROM OPERATIONS | $3,290 | $11,200 | Implemented |
NC0379 # 04 Y:2008 | 04 | 2008 | RECYCLE AIR FOR HEATING, VENTILATION AND AIR CONDITIONING | $2,284 | $3,000 | Implemented |
NC0379 # 01 Y:2008 | 01 | 2008 | ADJUST BURNERS FOR EFFICIENT OPERATION | $871 | $800 | Implemented |
NC0379 # 02 Y:2008 | 02 | 2008 | LOWER OPERATING PRESSURE OF CONDENSER (STEAM) | $333 | $100 | Implemented |
NC0379 # 08 Y:2008 | 08 | 2008 | DEVELOP A REPAIR/REPLACE POLICY | $834 | $1,728 | Implemented |
NC0379 # 06 Y:2008 | 06 | 2008 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $269 | $100 | Implemented |
NC0379 # 05 Y:2008 | 05 | 2008 | REDUCE THE PRESSURE OF COMPRESSED AIR TO THE MINIMUM REQUIRED | $237 | $50 | Implemented |
NC0379 # 07 Y:2008 | 07 | 2008 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $101 | $308 | Implemented |
MS0165 # 01 Y:2000 | 01 | 2000 | INSTALL TIMERS ON LIGHT SWITCHES IN LITTLE USED AREAS | $10,571 | $980 | Implemented |
MS0165 # 02 Y:2000 | 02 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $329 | $184 | Implemented |
MS0165 # 03 Y:2000 | 03 | 2000 | MAKE A PRACTICE OF TURNING OFF LIGHTS WHEN NOT NEEDED | $293 | $54 | Implemented |
MS0165 # 04 Y:2000 | 04 | 2000 | ELIMINATE/REDUCE AN OPERATION | $1,457 | $0 | Implemented |
HO0219 # 03 Y:2000 | 03 | 2000 | USE PHOTOCELL CONTROLS | $3,386 | $1,515 | Implemented |
HO0219 # 07 Y:2000 | 07 | 2000 | INSTALL / REPAIR INSULATION ON STEAM LINES | $3,102 | $4,641 | Implemented |
HO0219 # 06 Y:2000 | 06 | 2000 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $13,935 | $8,000 | Implemented |
HO0219 # 04 Y:2000 | 04 | 2000 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,271 | $1,500 | Implemented |
HO0219 # 02 Y:2000 | 02 | 2000 | INSTALL OCCUPANCY SENSORS | $2,714 | $5,000 | Implemented |
HO0219 # 01 Y:2000 | 01 | 2000 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,633 | $18,330 | Implemented |