IAC logo
Search IAC Recommendations
Sponsored by:
DOE MESC
IAC logo
Search IAC Recommendations
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.

33

matching recommendations
Reset
SIC 356 General Industrial Machinery
Row Colors Legend
no implementation information
Implemented
NOT Implemented
ID # Year Products Savings Cost Status
NC0531 # 02 Y:2014 02 2014 UPGRADE CONTROLS ON COMPRESSORS $80,544 $28,000 Implemented
NC0531 # 03 Y:2014 03 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $836 $240 Implemented
NC0531 # 04 Y:2014 04 2014 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $874 $1,255 Not Implemented
NC0531 # 05 Y:2014 05 2014 RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS $625 $100 Implemented
NC0531 # 06 Y:2014 06 2014 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $2,956 $1,935 Not Implemented
NC0531 # 07 Y:2014 07 2014 DEVELOP A REPAIR/REPLACE POLICY $2,202 $4,256 Implemented
NC0531 # 01 Y:2014 01 2014 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $17,220 $200 Implemented
OD0073 # 07 Y:1996 07 1996 USE DISTILLATION, EVAPORATION TO REMOVE CONTAMINANTS $12,085 $15,400 Not Implemented
OD0073 # 06 Y:1996 06 1996 BURN WASTE OIL FOR HEAT $2,167 $2,920 Not Implemented
OD0073 # 05 Y:1996 05 1996 USE A LESS EXPENSIVE METHOD OF WASTE REMOVAL $5,723 $20,400 Implemented
OD0073 # 04 Y:1996 04 1996 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,834 $400 Not Implemented
OD0073 # 03 Y:1996 03 1996 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $6,956 $6,885 Not Implemented
OD0073 # 02 Y:1996 02 1996 AVOID INTRODUCING HOT, HUMID, OR DIRTY AIR INTO HVAC SYSTEM $1,217 $1,860 Not Implemented
OD0073 # 01 Y:1996 01 1996 INSTALL TIMERS AND/OR THERMOSTATS $7,046 $60 Not Implemented
OD0032 # 02 Y:1995 02 1995 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,583 $800 Implemented
OD0032 # 03 Y:1995 03 1995 INSTALL OCCUPANCY SENSORS $1,789 $1,374 Not Implemented
OD0032 # 04 Y:1995 04 1995 RECOVER WASTE HEAT FROM EQUIPMENT $1,788 $1,447 Not Implemented
OD0032 # 05 Y:1995 05 1995 UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS $410 $396 Implemented
OD0032 # 06 Y:1995 06 1995 INSTALL SET-BACK TIMERS $1,343 $1,075 Not Implemented
OD0032 # 01 Y:1995 01 1995 TURN OFF EQUIPMENT WHEN NOT IN USE $5,570 $75 Not Implemented
OD0008 # 04 Y:1994 04 1994 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS $4,223 $4,432 Implemented
OD0008 # 03 Y:1994 03 1994 REPLACE CITY WATER WITH RECYCLED WATER VIA COOLING TOWER $2,718 $3,000 Implemented
OD0008 # 02 Y:1994 02 1994 UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS $1,213 $2,774 Not Implemented
OD0008 # 01 Y:1994 01 1994 ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES $1,410 $800 Implemented
OD0002 # 01 Y:1994 01 1994 INSTALL TIMERS AND/OR THERMOSTATS $7,710 $3,705 Implemented