Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
3,257
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
MO0026 # 02 Y:1991 | 02 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $3,614 | $306 | Implemented |
MO0026 # 03 Y:1991 | 03 | 1991 | USE PROPER THICKNESS OF INSULATION ON BUILDING ENVELOPE | $4,798 | $573 | Implemented |
MO0026 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $267 | $987 | Implemented |
MO0026 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $194 | $1,013 | Implemented |
MO0026 # 06 Y:1991 | 06 | 1991 | UTILIZE ENERGY-EFFICIENT BELTS AND OTHER IMPROVED MECHANISMS | $340 | $0 | Implemented |
MO0026 # 07 Y:1991 | 07 | 1991 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $222 | $300 | Implemented |
MO0026 # 08 Y:1991 | 08 | 1991 | IMPROVE LUBRICATION PRACTICES | $160 | $112 | Implemented |
KU0342 # 01 Y:1991 | 01 | 1991 | ELIMINATE OR REDUCE COMPRESSED AIR USAGE | $12,017 | $3,600 | Not Implemented |
KU0342 # 02 Y:1991 | 02 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $8,091 | $9,690 | Not Implemented |
KU0342 # 03 Y:1991 | 03 | 1991 | INSTALL TIMERS AND/OR THERMOSTATS | $774 | $1,140 | Not Implemented |
KU0342 # 04 Y:1991 | 04 | 1991 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $7,753 | $500 | Not Implemented |
KU0342 # 05 Y:1991 | 05 | 1991 | DE-ENERGIZE EXCESS TRANSFORMER CAPACITY | $4,942 | $100,000 | Not Implemented |
KU0342 # 06 Y:1991 | 06 | 1991 | INSTALL SET-BACK TIMERS | $2,678 | $550 | Not Implemented |
KU0342 # 07 Y:1991 | 07 | 1991 | REDUCE VENTILATION AIR | $1,195 | $200 | Not Implemented |
KU0342 # 08 Y:1991 | 08 | 1991 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $325 | $0 | Not Implemented |
UF0005 # 01 Y:1991 | 01 | 1991 | RESCHEDULE PLANT OPERATIONS OR REDUCE LOAD TO AVOID PEAKS | $11,778 | $0 | Not Implemented |
UF0005 # 02 Y:1991 | 02 | 1991 | KEEP LAMPS AND REFLECTORS CLEAN | $2,342 | $833 | Not Implemented |
UF0005 # 03 Y:1991 | 03 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,757 | $5,100 | Not Implemented |
UF0005 # 04 Y:1991 | 04 | 1991 | USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS | $418 | $3,150 | Not Implemented |
UF0005 # 05 Y:1991 | 05 | 1991 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $138 | $518 | Not Implemented |
UF0005 # 06 Y:1991 | 06 | 1991 | USE PROPERLY DESIGNED AND SIZED HVAC EQUIPMENT | $8,179 | $8,985 | Not Implemented |
UF0005 # 07 Y:1991 | 07 | 1991 | USE MOST EFFICIENT EQUIPMENT AT IT'S MAXIMUM CAPACITY AND LESS EFFICIENT EQUIPMENT ONLY WHEN NECESSARY | $9,878 | $0 | Not Implemented |
KU0336 # 01 Y:1991 | 01 | 1991 | RECOVER WASTE HEAT FROM EQUIPMENT | $21,491 | $19,500 | Implemented |
KU0336 # 02 Y:1991 | 02 | 1991 | USE DIRECT AIR SUPPLY TO EXHAUST HOODS | $15,055 | $18,000 | Implemented |
KU0336 # 03 Y:1991 | 03 | 1991 | IMPROVE AIR CIRCULATION WITH DESTRATIFICATION FANS / OTHER METHODS | $12,114 | $27,600 | Implemented |