IAC logo
IAC Assessment: WI0124
Sponsored by:
DOE MESC
IAC logo
IAC Assessment: WI0124
Implementation Grant Funding Opportunity Open
IMPORTANT: The grant program operates on a rolling basis and applications may be submitted at any time, with quarterly reviews.
Learn More
Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
IAC Center University of Wisconsin, Milwaukee
Assessment Year 1991
Principal Product PUMPS
NAICS n/a
SIC 3561 - Pumps And Pumping Equipment
Sales $10,000,000-$50,000,000
# of Employees 180
Plant Area (Sq.Ft.) 0
Annual Production 575,000 Pieces
Production Hrs. Annual 4,250
Location (State) IL
Source Yearly Cost Usage Unit Unit Cost
Electricity Usage $205,172 3,260,844 kWh $0.06
Natural Gas $43,103 13,117 MMBtu $3.29
TOTAL ENERGY COSTS $248,275
RECOMMENDED SAVINGS* $24,033 *Non-energy impacts
included in savings.
See recommendations below
IMPLEMENTED SAVINGS* -
#|Description Savings
Cost
Status Electricity Usage Natural Gas Electricity Usage Natural Gas
$ kWh $ MMBtu
01: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$7,961
Cost:
$800
$4,992 79,426 $2,969 902 $4,992
79,426
kWh
$2,969
902
MMBtu
02: 2.7261 INSTALL TIMERS AND/OR THERMOSTATS Savings:
$6,843
Cost:
$1,800
- - $6,843 2,080 -
-
kWh
$6,843
2,080
MMBtu
03: 2.3191 USE DEMAND CONTROLLER OR LOAD SHEDDER Savings:
$3,982
Cost:
$10,000
$3,982 - - - $3,982
-
kWh
-
-
MMBtu
04: 2.1311 REPLACE ELECTRICALLY-OPERATED EQUIPMENT WITH FOSSIL FUEL EQUIPMENT Savings:
$1,444
Cost:
$1,400
$1,859 29,601 $(-415) (-126) $1,859
29,601
kWh
$(-415)
(-126)
MMBtu
05: 2.6232 INSTALL SET-BACK TIMERS Savings:
$1,202
Cost:
$400
$1,202 19,050 - - $1,202
19,050
kWh
-
-
MMBtu
06: 2.2437 RECOVER WASTE HEAT FROM EQUIPMENT Savings:
$791
Cost:
$2,100
- - $791 240 -
-
kWh
$791
240
MMBtu
07: 2.4221 INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS Savings:
$300
Cost:
$640
$300 4,689 - - $300
4,689
kWh
-
-
MMBtu
08: 2.6124 ESTABLISH EQUIPMENT MAINTENANCE SCHEDULE Savings:
$763
Cost:
-
$763 14,068 - - $763
14,068
kWh
-
-
MMBtu
09: 2.4133 USE MOST EFFICIENT TYPE OF ELECTRIC MOTORS Savings:
$243
Cost:
$1,146
$243 3,810 - - $243
3,810
kWh
-
-
MMBtu
10: 2.7111 REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS Savings:
$192
Cost:
-
$192 2,931 - - $192
2,931
kWh
-
-
MMBtu
11: 2.4312 IMPROVE LUBRICATION PRACTICES Savings:
$166
Cost:
-
$166 2,638 - - $166
2,638
kWh
-
-
MMBtu
12: 2.6212 TURN OFF EQUIPMENT DURING BREAKS, REDUCE OPERATING TIME Savings:
$146
Cost:
-
$146 2,345 - - $146
2,345
kWh
-
-
MMBtu
TOTAL RECOMMENDED Savings:
$24,033
Cost:
$18,286
$13,845 158,558 $10,188 3,096 $13,845
158,558
kWh
$10,188
3,096
MMBtu
TOTAL IMPLEMENTED Savings:
-
Cost:
-
- - - - -
-
kWh
-
-
MMBtu
Savings
Cost
$ kWh $ MMBtu
Electricity Usage Natural Gas Electricity Usage Natural Gas