Implementation Grant Funding Opportunity Open
Qualifying* small and medium-sized US manufacturers, that received IAC or Combined Heat and Power Technical Assistance Partnership assessments between 2018 and 2024, can now apply for grants for implementation of assessment recommendations up 50% of qualifying* project costs with a maximum of $300,000 per manufacturer.
IMPORTANT: The grant program now operates on a rolling basis and applications may be submitted at any time through the year, with quarterly reviews.
*See Full Grant Solicitation for full qualification and selection details.
185
matching recommendationsSIC | 356 | General Industrial Machinery |
---|
Row Colors Legend |
---|
no implementation information |
Implemented |
NOT Implemented |
ID | # | Year | Products | Savings | Cost | Status |
---|---|---|---|---|---|---|
WM0193 # 03 Y:2023 | 03 | 2023 | USE OR REPLACE WITH ENERGY EFFICIENT SUBSTITUTES | $323 | $1,360 | Implemented |
WM0193 # 04 Y:2023 | 04 | 2023 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $286 | $500 | Implemented |
WM0116 # 06 Y:2018 | 06 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $1,729 | $1,833 | Implemented |
WM0116 # 04 Y:2018 | 04 | 2018 | USE WASTE HEAT FROM HOT FLUE GASES TO PREHEAT | $7,112 | $14,000 | Not Implemented |
WM0116 # 02 Y:2018 | 02 | 2018 | USE PHOTOCELL CONTROLS | $3,191 | $10,230 | Not Implemented |
WM0116 # 07 Y:2018 | 07 | 2018 | REPAIR OR REPLACE STEAM TRAPS | $1,678 | $3,960 | Implemented |
WM0116 # 08 Y:2018 | 08 | 2018 | REPLACE OBSOLETE BURNERS WITH MORE EFFICIENT ONES | $1,597 | $3,400 | Implemented |
WM0116 # 09 Y:2018 | 09 | 2018 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $1,233 | $3,124 | Not Implemented |
WM0116 # 10 Y:2018 | 10 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $395 | $720 | Implemented |
WM0116 # 01 Y:2018 | 01 | 2018 | USE SOLAR HEAT TO MAKE ELECTRICTY | $14,609 | $72,000 | Not Implemented |
WM0116 # 03 Y:2018 | 03 | 2018 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $7,895 | $14,722 | Implemented |
WM0116 # 05 Y:2018 | 05 | 2018 | USE COUNTER CURRENT RINSING TO REDUCE WASTE WATER | $3,017 | $3,000 | Not Implemented |
WM0067 # 10 Y:2015 | 10 | 2015 | REDUCE ILLUMINATION TO MINIMUM NECESSARY LEVELS | $7,592 | $640 | Implemented |
WM0067 # 14 Y:2015 | 14 | 2015 | INSTALL OCCUPANCY SENSORS | $731 | $1,876 | Not Implemented |
WM0067 # 13 Y:2015 | 13 | 2015 | RECHARGE BATTERIES ON DURING OFF-PEAK DEMAND PERIODS | $3,678 | $0 | Implemented |
WM0067 # 02 Y:2015 | 02 | 2015 | RECOVER HEAT FROM EXHAUSTED STEAM, HOT AIR OR HOT WATER | $44,425 | $42,690 | Not Implemented |
WM0067 # 03 Y:2015 | 03 | 2015 | COMBINE UTILITY METERS | $35,185 | $4,450 | Not Implemented |
WM0067 # 04 Y:2015 | 04 | 2015 | LOWER TEMPERATURE DURING THE WINTER SEASON AND VICE-VERSA | $25,416 | $0 | Implemented |
WM0067 # 05 Y:2015 | 05 | 2015 | INSTALL VINYL STRIP / HIGH SPEED / AIR CURTAIN DOORS | $12,203 | $7,680 | Not Implemented |
WM0067 # 06 Y:2015 | 06 | 2015 | INSULATE BARE EQUIPMENT | $7,737 | $654 | Not Implemented |
WM0067 # 08 Y:2015 | 08 | 2015 | ELIMINATE LEAKS IN INERT GAS AND COMPRESSED AIR LINES/ VALVES | $8,586 | $1,680 | Implemented |
WM0067 # 07 Y:2015 | 07 | 2015 | RECOVER WASTE HEAT FROM EQUIPMENT | $9,191 | $1,600 | Not Implemented |
WM0067 # 09 Y:2015 | 09 | 2015 | INSTALL COMPRESSOR AIR INTAKES IN COOLEST LOCATIONS | $4,111 | $1,245 | Not Implemented |
WM0067 # 11 Y:2015 | 11 | 2015 | UTILIZE HIGHER EFFICIENCY LAMPS AND/OR BALLASTS | $6,495 | $10,871 | Implemented |
WM0067 # 12 Y:2015 | 12 | 2015 | CONTRACT A WOOD PALLET RECYCLING COMPANY | $5,737 | $0 | Not Implemented |